» Articles » PMID: 26319247

Effect of Laser-assisted Bleaching with Nd:YAG and Diode Lasers on Shear Bond Strength of Orthodontic Brackets

Overview
Journal Lasers Med Sci
Publisher Springer
Date 2015 Aug 31
PMID 26319247
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the present study was to assess the effect of laser-assisted bleaching with neodymium:yttrium-aluminum-garnet (Nd:YAG) and diode lasers on shear bond strength (SBS) of orthodontic brackets. One hundred and four extracted human premolars were randomly divided into four groups: group 1: No bleaching applied (control group); group 2: Teeth bleached with 40 % hydrogen peroxide; group 3: Teeth treated with 30 % hydrogen peroxide activated with Nd:YAG laser (1064 nm, 2.5 W, 25 Hz, pulse duration of 100 μs, 6 mm distance); and group 4: Teeth treated with 30 % hydrogen peroxide activated with diode laser (810 nm, 1 W, CW, 6 mm distance). Equal numbers of teeth in groups 2, 3, and 4 were bonded at start, 1 h, 24 h, and 1 week after bleaching. A universal testing machine measured the SBS of the samples 24 h after bonding. After bracket debonding, the amount of residual adhesive on the enamel surface was observed under a stereomicroscope to determine the adhesive remnant index (ARI) scores. The SBS in the unbleached group was significantly higher than that in the bleached groups bonded immediately and 1 h after laser-assisted bleaching (P < 0.05). In groups 3 and 4 at start and group 2 at start and 1 h after laser-assisted bleaching, the SBS was found to be significantly lower than that in the control group. Significant differences in the ARI scores existed among groups as well. The SBS of brackets seems to increase quickly within an hour after laser-assisted bleaching and 24 h after conventional bleaching. Thus, this protocol can be recommended if it is necessary to bond the brackets on the same day of bleaching.

Citing Articles

The Effect of Two Different Wavelengths of Diode Laser on the Shear Bond Strength of Composite to Dental Enamel after Bleaching Process: An In Vitro Study.

Pourmahmoudian R, Solimei L, Benedicenti S, Saberi S, Shahabi S Bioengineering (Basel). 2024; 11(6).

PMID: 38927795 PMC: 11200604. DOI: 10.3390/bioengineering11060559.


Comparative evaluation of bond strength of diode and neodymium-doped:Yttrium aluminum garnet-assisted bleached enamel with nanofilled composite: An study.

Dube R, Tandale A, Talreja T, Krishnakumar K, Kokate P, Mulay S J Conserv Dent Endod. 2024; 27(4):378-382.

PMID: 38779207 PMC: 11108415. DOI: 10.4103/JCDE.JCDE_340_23.


Evaluation of the Effect of Phosphoric Acid or Er: YAG Laser on the Shear Bond Strength of Orthodontic Brackets to Enamel Surfaces Followed by 980-Laser Assisted Bleaching: An In Vitro Study.

Oladzad M, Chiniforush N, Bahrami R, Mirhashemi A J Lasers Med Sci. 2024; 14:e62.

PMID: 38318224 PMC: 10843250. DOI: 10.34172/jlms.2023.62.


Effect of sodium ascorbate on the shear bond strength of orthodontic brackets to bleached enamel using universal dental adhesive.

Sadeghian S, Fathpour K, Biglari M Dent Res J (Isfahan). 2023; 20:28.

PMID: 36960020 PMC: 10028585. DOI: 10.4103/1735-3327.369630.


Spectrophotometric analysis of the effectiveness of a novel in-office laser-assisted tooth bleaching method using Er,Cr:YSGG laser.

Dionysopoulos D, Strakas D, Tolidis K, Tsitrou E, Koumpia E, Koliniotou-Koumpia E Lasers Med Sci. 2017; 32(8):1811-1818.

PMID: 28685202 DOI: 10.1007/s10103-017-2274-y.

References
1.
Kinoshita J, Jafarzadeh H, Forghani M . Vital Bleaching of Tetracycline-Stained Teeth by Using KTP Laser: A Case Report. Eur J Dent. 2009; 3(3):229-32. PMC: 2741196. View

2.
Titley K, TORNECK C, Ruse N . The effect of carbamide-peroxide gel on the shear bond strength of a microfil resin to bovine enamel. J Dent Res. 1992; 71(1):20-4. DOI: 10.1177/00220345920710010301. View

3.
do Rego M, dos Santos R, Leal L, Braga C . Evaluation of the influence of dental bleaching with 35% hydrogen peroxide in orthodontic bracket shear bond strength. Dental Press J Orthod. 2013; 18(2):95-100. DOI: 10.1590/s2176-94512013000200020. View

4.
Fornaini C, Lagori G, Merigo E, Meleti M, Manfredi M, Guidotti R . Analysis of shade, temperature and hydrogen peroxide concentration during dental bleaching: in vitro study with the KTP and diode lasers. Lasers Med Sci. 2011; 28(1):1-6. DOI: 10.1007/s10103-011-1037-4. View

5.
Oztas E, Bagdelen G, Kilicoglu H, Ulukapi H, Aydin I . The effect of enamel bleaching on the shear bond strengths of metal and ceramic brackets. Eur J Orthod. 2011; 34(2):232-7. DOI: 10.1093/ejo/cjq193. View