Yamashita T, Ikeda H, Otsuka R, Torikoshi S, Sano N, Hayase M
J Neuroendovasc Ther. 2023; 14(10):447-453.
PMID: 37502656
PMC: 10370532.
DOI: 10.5797/jnet.cr.2020-0044.
Sakata H, Ezura M, Abe T, Ishida T, Endo H, Inoue T
J Neuroendovasc Ther. 2023; 15(12):823-828.
PMID: 37502002
PMC: 10370932.
DOI: 10.5797/jnet.tn.2020-0155.
Cay F, Arat A
AJNR Am J Neuroradiol. 2022; 43(8):1152-1157.
PMID: 35902123
PMC: 9575423.
DOI: 10.3174/ajnr.A7583.
Hou K, Yu J
Front Neurol. 2022; 13:829143.
PMID: 35401410
PMC: 8990925.
DOI: 10.3389/fneur.2022.829143.
McEachern J, Iancu D, van Adel B, Drake B, Kaderali Z, Spirou M
Interv Neuroradiol. 2022; 29(2):134-140.
PMID: 35112888
PMC: 10152819.
DOI: 10.1177/15910199221077588.
"Shelf" Technique Using a Novel Braided Self-Expandable Stent for the Treatment of Wide-Necked Bifurcation Aneurysms.
Maus V, Weber W, Fischer S
Clin Neuroradiol. 2021; 31(4):1187-1193.
PMID: 34283247
PMC: 8648644.
DOI: 10.1007/s00062-021-01032-2.
The evolution of intracranial aneurysm treatment techniques and future directions.
Lee K, Zhang J, Nguyen V, Han J, Johnson J, Kirollos R
Neurosurg Rev. 2021; 45(1):1-25.
PMID: 33891216
PMC: 8827391.
DOI: 10.1007/s10143-021-01543-z.
Analysis of branch artery orifice angulation: Feasibility of the shelf technique for the treatment of wide-neck bifurcation aneurysms.
Onay M, Binboga A, Altay C
Interv Neuroradiol. 2020; 27(3):362-371.
PMID: 33222557
PMC: 8190934.
DOI: 10.1177/1591019920976252.
Hemodynamic differences by increasing low profile visualized intraluminal support (LVIS) stent local compaction across intracranial aneurysm orifice.
Tian Z, Zhang M, Li G, Jin R, Leng X, Zhang Y
Interv Neuroradiol. 2020; 26(5):557-565.
PMID: 32830566
PMC: 7645191.
DOI: 10.1177/1591019920952903.
The use of single low-profile visualized intraluminal support stent-assisted coiling in the treatment of middle cerebral artery bifurcation unruptured wide-necked aneurysm.
Yan Y, Zeng Z, Wu Y, Xiong J, Zhao K, Hong B
Interv Neuroradiol. 2020; 26(4):461-467.
PMID: 31979996
PMC: 7446575.
DOI: 10.1177/1591019920901925.
Comparison of endovascular treatment for middle cerebral artery aneurysm with a low-profile visualized intraluminal support stent or pipeline embolization device.
Lu P, Zhang Y, Niu H, Wang Y
Exp Ther Med. 2019; 18(3):2072-2078.
PMID: 31410163
PMC: 6676140.
DOI: 10.3892/etm.2019.7775.
Endovascular treatment of middle cerebral artery aneurysm with a (LVIS) device: Comparison of LVIS stent and non-LVIS stent.
Chen F, Fang X
Exp Ther Med. 2019; 17(3):1656-1662.
PMID: 30783434
PMC: 6364188.
DOI: 10.3892/etm.2018.7139.
In Vitro Evaluation of Fusiform-Shaped Stents for Wide-Neck Intracranial Aneurysm Treatment.
Jia Z, Jiang Y, Woo J, Hwang S, Lim O, Kim T
Neurointervention. 2018; 13(2):117-123.
PMID: 30196682
PMC: 6132037.
DOI: 10.5469/neuroint.2018.00976.
The LUNA aneurysm embolization system for intracranial aneurysm treatment: short-term, mid-term and long-term clinical and angiographic results.
Piotin M, Biondi A, Sourour N, Mounayer C, Jaworski M, Mangiafico S
J Neurointerv Surg. 2018; 10(12):e34.
PMID: 29669856
PMC: 6288707.
DOI: 10.1136/neurintsurg-2018-013767.
Utility of bulging technique for endovascular treatment of small and wide-necked aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr.) device: A case report and review of the literature.
Inoue A, Tagawa M, Matsumoto S, Nishikawa M, Kusakabe K, Watanabe H
Interv Neuroradiol. 2017; 24(2):125-129.
PMID: 29160136
PMC: 5847007.
DOI: 10.1177/1591019917743065.
Flanking the fenestration: circumferential limb-to-limb stent-assisted coiling of a basilar artery fenestration aneurysm.
Morrison J, Alexander M, Dowd C, Cooke D
BMJ Case Rep. 2017; 2017.
PMID: 29030497
PMC: 5695425.
DOI: 10.1136/bcr-2017-013252.
Preliminary Experience with Stent-Assisted Coiling of Aneurysms Arising from Small (<2.5 mm) Cerebral Vessels Using The Low-Profile Visualized Intraluminal Support Device.
Wang C, Li W, Feng Z, Hong B, Xu Y, Liu J
AJNR Am J Neuroradiol. 2017; 38(6):1163-1168.
PMID: 28385886
PMC: 7960081.
DOI: 10.3174/ajnr.A5145.
Single-center experience in the endovascular treatment of wide-necked intracranial aneurysms with a bridging intra-/extra-aneurysm implant (pCONus).
Fischer S, Weber A, Titschert A, Brenke C, Kowoll A, Weber W
J Neurointerv Surg. 2015; 8(11):1186-1191.
PMID: 26658279
PMC: 5099317.
DOI: 10.1136/neurintsurg-2015-012004.