Abstract

Purpose: We present a volumetric sampling method that rotates the spiral interleaves of a stack of spirals (SOSP) trajectory for reduced aliasing artifacts using parallel imaging with undersampling.

Methods: The aliasing pattern in an undersampled SOSP acquisition was modified by consecutively rotating spiral interleaves in each phase-encoding plane. This allows a sampling scheme with a high reduction factor when using a volumetric multireceiver array. Phantom and in vivo brain images at a resolution of 1 × 1 × 2 mm(3) were acquired at 3T using a 32-channel coil. Images reconstructed with a reduction factor of 16 were compared for aliasing artifacts and geometry factor (g-factor).

Results: Phantom and in vivo brain image results revealed that the rotated SOSP acquisition with a reduction factor of 16 produces images with reduced aliasing and lower g-factors than images acquired without rotation.

Conclusion: The proposed rotated SOSP sampling method is a highly efficient way to maximize the encoding power of volumetric receiver arrays in parallel imaging and is applicable to rapid volumetric scanning, including susceptibility-weighted imaging and functional MRI. Magn Reson Med 76:127-135, 2016. © 2015 Wiley Periodicals, Inc.

Citing Articles

Three dimensional radial echo planar imaging for functional MRI.

Rettenmeier C, Maziero D, Stenger V Magn Reson Med. 2021; 87(1):193-206.

PMID: 34411342 PMC: 8616809. DOI: 10.1002/mrm.28980.


Mono-planar T-Hex: Speed and flexibility for high-resolution 3D imaging.

Engel M, Kasper L, Wilm B, Dietrich B, Patzig F, Vionnet L Magn Reson Med. 2021; 87(1):272-280.

PMID: 34398985 PMC: 9292510. DOI: 10.1002/mrm.28979.


Fast 3D MR elastography of the whole brain using spiral staircase: Data acquisition, image reconstruction, and joint deblurring.

Peng X, Sui Y, Trzasko J, Glaser K, Huston 3rd J, Ehman R Magn Reson Med. 2021; 86(4):2011-2024.

PMID: 34096097 PMC: 8498799. DOI: 10.1002/mrm.28855.


15 Years MR-encephalography.

Hennig J, Kiviniemi V, Riemenschneider B, Barghoorn A, Akin B, Wang F MAGMA. 2020; 34(1):85-108.

PMID: 33079327 PMC: 7910380. DOI: 10.1007/s10334-020-00891-z.


Rotated spiral RARE for high spatial and temporal resolution volumetric arterial spin labeling acquisition.

Munsch F, Taso M, Zhao L, Lebel R, Guidon A, Detre J Neuroimage. 2020; 223:117371.

PMID: 32931943 PMC: 9470008. DOI: 10.1016/j.neuroimage.2020.117371.


References
1.
Robson P, Grant A, Madhuranthakam A, Lattanzi R, Sodickson D, McKenzie C . Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions. Magn Reson Med. 2008; 60(4):895-907. PMC: 2838249. DOI: 10.1002/mrm.21728. View

2.
Agulleiro J, Garzon E, Garcia I, Fernandez J . Vectorization with SIMD extensions speeds up reconstruction in electron tomography. J Struct Biol. 2010; 170(3):570-5. DOI: 10.1016/j.jsb.2010.01.008. View

3.
Irarrazabal P, Nishimura D . Fast three dimensional magnetic resonance imaging. Magn Reson Med. 1995; 33(5):656-62. DOI: 10.1002/mrm.1910330510. View

4.
Hu Y, Glover G . Three-dimensional spiral technique for high-resolution functional MRI. Magn Reson Med. 2007; 58(5):947-51. DOI: 10.1002/mrm.21328. View

5.
Qian Y, Boada F . Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging. Magn Reson Med. 2008; 60(1):135-45. PMC: 11864364. DOI: 10.1002/mrm.21620. View