Ultrasonography As a Guiding Method in Breast Micro-Calcification Vacuum-Assisted Biopsies

Overview
Journal Ultraschall Med
Date 2015 Jul 23
PMID 26200720
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess the visibility of breast micro-calcifications using ultrasonography (US) and the accuracy and clinical usefulness of vacuum-assisted biopsy (VAB) using US guidance (USVAB) as compared to stereotactic guidance (SVAB).

Materials And Methods: The study material comprised 158 retrospectively reviewed micro-calcification cases examined with US before VAB. The pre-biopsy US positivity frequency distributions were calculated, and the sensitivity, specificity and accuracy of VAB determined by comparing VAB histology with the surgical pathology or a 12-month follow-up.

Results: 158 US examinations yielded 80 positive and 78 negative results. US positivity correlated to a large size and a suspicious BI-RADS category of the calcifications. USVAB was performed in 49 cases with 61 % malignant, 12 % high-risk and 27 % benign results. The percentages for the 109 SVAB cases were 40 %, 28 % and 32 %, respectively. Specimen radiography demonstrated calcifications in 48 of the 49 (98 %) USVAB cases and in 107 of the 109 (98 %) SVAB cases. The overall accuracy of VAB was 94 % (USVAB 98 %, SVAB 94 %), the sensitivity was 88 % (USVAB 97 %, SVAB 83 %), and the specificity was 100 %. The higher sensitivity of USVAB was due to an accumulation of atypical hyperplasia diagnoses in the SVAB group. The final diagnosis was invasive ductal carcinoma in 21 US-positive and in 4 US-negative cases.

Conclusion: Approximately 50 % of mammographically detected micro-calcifications could be detected with ultrasonography. US was found to be a valuable alternative guidance method for vacuum-assisted biopsy of micro-calcifications with a technical success rate and diagnostic accuracy well comparable to the stereotactic method.

Citing Articles

Predicting Non-Mass Breast Cancer Utilizing Ultrasound and Molybdenum Target X-Ray Characteristics.

Wang Z, Cao X, Jia C, Mi N, Li T, Wang J J Multidiscip Healthc. 2024; 17:4267-4276.

PMID: 39246563 PMC: 11378988. DOI: 10.2147/JMDH.S473370.


Analysis of the causes of false negative and false positive results of preoperative axillary ultrasound in patients with early breast cancer - a single-centre study.

Nowikiewicz T, Nowak A, Wisniewska M, Wisniewski M, Nowikiewicz M, Zegarski W Contemp Oncol (Pozn). 2019; 22(4):247-251.

PMID: 30783389 PMC: 6377422. DOI: 10.5114/wo.2018.82644.