Late Restenosis After Paclitaxel-Coated Balloon Angioplasty Occurs in Patients With Drug-Eluting Stent Restenosis

Abstract

Background: There are currently inadequate data on whether "late restenosis" occurs after paclitaxel-coated balloon (PCB) angioplasty for in-stent restenosis (ISR) lesions.

Objectives: To evaluate the long-term safety and efficacy of PCB angioplasty, we investigated serial clinical and angiographic outcomes after PCB angioplasty for ISR lesions.

Methods: Between September 2008 and December 2012, PCB angioplasty was performed in 468 patients with 550 ISR lesions (bare-metal stent restenosis [BMS-ISR]: 114 lesions, drug-eluting stent restenosis [DES-ISR]: 436 lesions). Two serial angiographic follow-ups were routinely planned for the patients (at 6 and 18 months after the procedure).

Results: Early follow-up (6 months) angiography was performed for 488 lesions (89%), and recurrent restenosis occurred in 13 lesions (13.0%) in the BMS-ISR group and in 82 lesions (21.1%) in the DES-ISR group. Target lesion revascularization was performed for 7 lesions (7.0%) in the BMS-ISR group and 54 lesions (13.9%) in the DES-ISR group. Late follow-up (18 months) angiography was performed for 377 (88%) of the remaining 427 lesions (excluding target lesion revascularization lesions), and late restenosis was found in 2 lesions (2.5%) in the BMS-ISR group and 50 lesions (16.8%) in the DES-ISR group. Delayed late lumen loss was significantly larger in the DES-ISR group. Previous stent size ≤2.5 mm, percentage diameter stenosis after the procedure, and in-stent occlusion lesion were independent predictors of early restenosis. DES-ISR, percentage diameter stenosis at early follow-up, and hemodialysis were independent predictors of late restenosis.

Conclusions: Late restenosis occurs after PCB angioplasty for DES-ISR lesions.

Citing Articles

Nanoparticle-based approaches for treating restenosis after vascular injury.

Zhao L, Feng L, Shan R, Huang Y, Shen L, Fan M Front Pharmacol. 2024; 15:1427651.

PMID: 39512830 PMC: 11540800. DOI: 10.3389/fphar.2024.1427651.


Drug-coated balloon therapy is more effective in treating late drug-eluting stent in-stent restenosis than the early occurring one-a systematic review and meta-analysis.

Kulyassa P, Engh M, Vamosi P, Fehervari P, Hegyi P, Merkely B Front Cardiovasc Med. 2023; 10:1062130.

PMID: 37342438 PMC: 10277682. DOI: 10.3389/fcvm.2023.1062130.


Drug-loaded balloon with built-in NIR controlled tip-separable microneedles for long-effective arteriosclerosis treatment.

Huang L, Fang H, Zhang T, Hu B, Liu S, Lv F Bioact Mater. 2022; 23:526-538.

PMID: 36514389 PMC: 9730155. DOI: 10.1016/j.bioactmat.2022.11.015.


Clinical Results of Drug-Coated Balloon Treatment in a Large-Scale Multicenter Korean Registry Study.

Lee S, Cho Y, Kim S, Hong Y, Koo B, Bae J Korean Circ J. 2022; 52(6):444-454.

PMID: 35491479 PMC: 9160640. DOI: 10.4070/kcj.2021.0261.


Open-Label Multicenter Registry on the Outcomes of In-Stent Restenosis Treated by Balloon Angioplasty with Optical Frequency Domain Imaging in the Superficial Femoral Artery (ISLAND-SFA Study).

Yanaka K, Konishi A, Shinke T, Kozuki A, Kawamori H, Tsukiyama Y Ann Vasc Dis. 2021; 13(3):291-299.

PMID: 33384733 PMC: 7751072. DOI: 10.3400/avd.oa.20-00077.