» Articles » PMID: 26134791

X-ray Pulse Wavefront Metrology Using Speckle Tracking

Overview
Date 2015 Jul 3
PMID 26134791
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

An instrument allowing the quantitative analysis of X-ray pulsed wavefronts is presented and its processing method explained. The system relies on the X-ray speckle tracking principle to accurately measure the phase gradient of the X-ray beam from which beam optical aberrations can be deduced. The key component of this instrument, a semi-transparent scintillator emitting visible light while transmitting X-rays, allows simultaneous recording of two speckle images at two different propagation distances from the X-ray source. The speckle tracking procedure for a reference-less metrology mode is described with a detailed account on the advanced processing schemes used. A method to characterize and compensate for the imaging detector distortion, whose principle is also based on speckle, is included. The presented instrument is expected to find interest at synchrotrons and at the new X-ray free-electron laser sources under development worldwide where successful exploitation of beams relies on the availability of an accurate wavefront metrology.

Citing Articles

Review and experimental comparison of speckle-tracking algorithms for X-ray phase contrast imaging.

Celestre R, Quenot L, Ninham C, Brun E, Fardin L J Synchrotron Radiat. 2024; 32(Pt 1):180-199.

PMID: 39689035 PMC: 11708844. DOI: 10.1107/S1600577524010117.


X-ray-to-visible light-field detection through pixelated colour conversion.

Yi L, Hou B, Zhao H, Liu X Nature. 2023; 618(7964):281-286.

PMID: 37165192 PMC: 10247359. DOI: 10.1038/s41586-023-05978-w.


Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument.

Makarov S, Makita M, Nakatsutsumi M, Pikuz T, Ozaki N, Preston T J Synchrotron Radiat. 2023; 30(Pt 1):208-216.

PMID: 36601939 PMC: 9814068. DOI: 10.1107/S1600577522006245.


High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography.

Qiao Z, Shi X, Wojcik M, Assoufid L J Imaging. 2021; 7(12).

PMID: 34940716 PMC: 8705295. DOI: 10.3390/jimaging7120249.


X-Ray Single-Grating Interferometry for Wavefront Measurement and Correction of Hard X-Ray Nanofocusing Mirrors.

Yamada J, Inoue T, Nakamura N, Kameshima T, Yamauchi K, Matsuyama S Sensors (Basel). 2020; 20(24).

PMID: 33371522 PMC: 7767480. DOI: 10.3390/s20247356.


References
1.
Martinez-Criado G, Tucoulou R, Cloetens P, Bleuet P, Bohic S, Cauzid J . Status of the hard X-ray microprobe beamline ID22 of the European Synchrotron Radiation Facility. J Synchrotron Radiat. 2011; 19(Pt 1):10-8. DOI: 10.1107/S090904951104249X. View

2.
Zanette I, Zhou T, Burvall A, Lundstrom U, Larsson D, Zdora M . Speckle-based x-ray phase-contrast and dark-field imaging with a laboratory source. Phys Rev Lett. 2014; 112(25):253903. DOI: 10.1103/PhysRevLett.112.253903. View

3.
Kewish C, Guizar-Sicairos M, Liu C, Qian J, Shi B, Benson C . Reconstruction of an astigmatic hard X-ray beam and alignment of K-B mirrors from ptychographic coherent diffraction data. Opt Express. 2010; 18(22):23420-7. DOI: 10.1364/OE.18.023420. View

4.
Kayser Y, Rutishauser S, Katayama T, Ohashi H, Kameshima T, Flechsig U . Wavefront metrology measurements at SACLA by means of X-ray grating interferometry. Opt Express. 2014; 22(8):9004-15. DOI: 10.1364/OE.22.009004. View

5.
Brady G, Fienup J . Nonlinear optimization algorithm for retrieving the full complex pupil function. Opt Express. 2009; 14(2):474-86. DOI: 10.1364/opex.14.000474. View