» Articles » PMID: 26133289

Intra-operative Gaps Affect Outcome and Postoperative Kinematics in Vivo Following Cruciate-retaining Total Knee Arthroplasty

Overview
Journal Int Orthop
Specialty Orthopedics
Date 2015 Jul 3
PMID 26133289
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The following investigation evaluates the effect of intra-operative gaps after posterior cruciate ligament-retaining total knee arthroplasty using two-dimensional/three-dimensional registration and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).

Methods: Patients were divided into two groups according to their 90°-0° component gap changes using a device designed by our laboratory. The wide gap group was defined as more than 3 mm (4.3 ± 0.7 mm), and the narrow gap group was defined as less than 3 mm (1.3 ± 1.3 mm).

Results: Under non-WB (weight bearing) conditions, the wide flexion gap group (N = 10) showed a significant anterior displacement of the medial femoral condyle as compared with the narrow flexion gap group (N = 20). Despite no significant differences observed under WB conditions, both femoral condyle positions during flexion were significantly more posterior than during extension. WOMAC of the tight gap group showed worse scores for two functional items demanding knee flexion (bending to floor and getting on/off toilet).

Conclusion: The large flexion gap could influence the late rollback under non-WB conditions and better WOMAC functional scores in the flexion items. Three to four millimetre laxity at 90°-0° component gaps may be adequate and might be necessary to carry out daily life activities.

Citing Articles

Mobile bearing shows larger rollback motion than fixed bearing in total knee arthroplasty using a medial stabilising technique with a navigation system.

Tsushima T, Sasaki E, Sasaki S, Oishi K, Sakamoto Y, Kimura Y J Exp Orthop. 2024; 11(3):e12053.

PMID: 38868126 PMC: 11167407. DOI: 10.1002/jeo2.12053.


Gross Appearances of the Posterior Cruciate Ligament Correlate With Its Histological Features but not With In Vivo Function in Cruciate-Retaining Total Knee Arthroplasty.

Hayashi S, Miyazaki S Cureus. 2023; 15(4):e38128.

PMID: 37252485 PMC: 10212607. DOI: 10.7759/cureus.38128.


Shear wave tensiometry tracks reductions in collateral ligament tension due to incremental releases.

Blomquist M, Blank J, Schmitz D, Thelen D, Roth J J Orthop Res. 2022; 41(3):524-533.

PMID: 35716160 PMC: 9759618. DOI: 10.1002/jor.25400.


Shear wave speeds track axial stress in porcine collateral ligaments.

Blank J, Thelen D, Roth J J Mech Behav Biomed Mater. 2020; 105:103704.

PMID: 32279848 PMC: 7211043. DOI: 10.1016/j.jmbbm.2020.103704.


Characterizing fluoroscopy based kinematic accuracy as a function of pulse width and velocity.

Ellingson A, Mozingo J, Magnuson D, Pagnano M, Zhao K J Biomech. 2016; 49(15):3741-3745.

PMID: 27769514 PMC: 5242255. DOI: 10.1016/j.jbiomech.2016.09.044.


References
1.
Hananouchi T . Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation. Int Orthop. 2014; 39(4):659-65. DOI: 10.1007/s00264-014-2536-2. View

2.
Komistek R, Mahfouz M, Bertin K, Rosenberg A, Kennedy W . In vivo determination of total knee arthroplasty kinematics: a multicenter analysis of an asymmetrical posterior cruciate retaining total knee arthroplasty. J Arthroplasty. 2008; 23(1):41-50. DOI: 10.1016/j.arth.2007.01.016. View

3.
Futai K, Tomita T, Yamazaki T, Tamaki M, Yoshikawa H, Sugamoto K . In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions. Knee Surg Sports Traumatol Arthrosc. 2010; 19(6):914-20. DOI: 10.1007/s00167-010-1262-6. View

4.
Dennis D, Komistek R, Mahfouz M . In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res. 2003; (410):114-30. DOI: 10.1097/01.blo.0000062385.79828.72. View

5.
Kurita M, Tomita T, Yamazaki T, Fujii M, Futai K, Shimizu N . In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion. Int Orthop. 2012; 36(12):2465-71. PMC: 3508061. DOI: 10.1007/s00264-012-1673-8. View