» Articles » PMID: 26123184

A Straightforward Approach for Gated STED-FCS to Investigate Lipid Membrane Dynamics

Overview
Journal Methods
Specialty Biochemistry
Date 2015 Jul 1
PMID 26123184
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Recent years have seen the development of multiple technologies to investigate, with great spatial and temporal resolution, the dynamics of lipids in cellular and model membranes. One of these approaches is the combination of far-field super-resolution stimulated-emission-depletion (STED) microscopy with fluorescence correlation spectroscopy (FCS). STED-FCS combines the diffraction-unlimited spatial resolution of STED microscopy with the statistical accuracy of FCS to determine sub-millisecond-fast molecular dynamics with single-molecule sensitivity. A unique advantage of STED-FCS is that the observation spot for the FCS data recordings can be tuned to sub-diffraction scales, i.e. <200 nm in diameter, in a gradual manner to investigate fast diffusion of membrane-incorporated labelled entities. Unfortunately, so far the STED-FCS technology has mostly been applied on a few custom-built setups optimised for far-red fluorescent emitters. Here, we summarise the basics of the STED-FCS technology and highlight how it can give novel details into molecular diffusion modes. Most importantly, we present a straightforward way for performing STED-FCS measurements on an unmodified turnkey commercial system using a time-gated detection scheme. Further, we have evaluated the STED-FCS performance of different commonly used green emitting fluorescent dyes applying freely available, custom-written analysis software.

Citing Articles

Diffusion and interaction dynamics of the cytosolic peroxisomal import receptor PEX5.

Galiani S, Reglinski K, Carravilla P, Barbotin A, Urbancic I, Ott J Biophys Rep (N Y). 2022; 2(2):None.

PMID: 36299769 PMC: 9586885. DOI: 10.1016/j.bpr.2022.100055.


Advanced Static and Dynamic Fluorescence Microscopy Techniques to Investigate Drug Delivery Systems.

Cardellini J, Balestri A, Montis C, Berti D Pharmaceutics. 2021; 13(6).

PMID: 34208080 PMC: 8230741. DOI: 10.3390/pharmaceutics13060861.


Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique.

Valli J, Garcia-Burgos A, Rooney L, Vale de Melo E Oliveira B, Duncan R, Rickman C J Biol Chem. 2021; 297(1):100791.

PMID: 34015334 PMC: 8246591. DOI: 10.1016/j.jbc.2021.100791.


Super-Resolution STED Microscopy-Based Mobility Studies of the Viral Env Protein at HIV-1 Assembly Sites of Fully Infected T-Cells.

Chojnacki J, Eggeling C Viruses. 2021; 13(4).

PMID: 33918253 PMC: 8067239. DOI: 10.3390/v13040608.


Background Reduction in STED-FCS Using a Bivortex Phase Mask.

Barbotin A, Urbancic I, Galiani S, Eggeling C, Booth M ACS Photonics. 2020; 7(7):1742-1753.

PMID: 32685609 PMC: 7366504. DOI: 10.1021/acsphotonics.0c00388.


References
1.
Schwille P, Korlach J, Webb W . Fluorescence correlation spectroscopy with single-molecule sensitivity on cell and model membranes. Cytometry. 1999; 36(3):176-82. DOI: 10.1002/(sici)1097-0320(19990701)36:3<176::aid-cyto5>3.0.co;2-f. View

2.
Digman M, Gratton E . Imaging barriers to diffusion by pair correlation functions. Biophys J. 2009; 97(2):665-73. PMC: 2711318. DOI: 10.1016/j.bpj.2009.04.048. View

3.
Sahl S, Leutenegger M, Hell S, Eggeling C . High-resolution tracking of single-molecule diffusion in membranes by confocalized and spatially differentiated fluorescence photon stream recording. Chemphyschem. 2014; 15(4):771-83. DOI: 10.1002/cphc.201301090. View

4.
Hell S . Microscopy and its focal switch. Nat Methods. 2009; 6(1):24-32. DOI: 10.1038/nmeth.1291. View

5.
Hotta J, Fron E, Dedecker P, Janssen K, Li C, Mullen K . Spectroscopic rationale for efficient stimulated-emission depletion microscopy fluorophores. J Am Chem Soc. 2010; 132(14):5021-3. DOI: 10.1021/ja100079w. View