Analysis of Prostate Deformation During a Course of Radiation Therapy for Prostate Cancer

Abstract

Purpose: Accurate analysis of the correlation between deformation of the prostate and displacement of its center of gravity (CoG) is important for efficient radiation therapy for prostate cancer. In this study, we addressed this problem by introducing a new analysis approach.

Method: A planning computed tomography (CT) scan and 7 repeat cone-beam CT scans during the course of treatment were obtained for 19 prostate cancer patients who underwent three-dimensional conformal radiation therapy. A single observer contoured the prostate gland only. To evaluate the local deformation of the prostate, it was divided into 12 manually defined segments. Prostate deformation was calculated using in-house developed software. The correlation between the displacement of the CoG and the local deformation of the prostate was evaluated using multiple regression analysis.

Results: The mean value and standard deviation (SD) of the prostate deformation were 0.6 mm and 1.7 mm, respectively. For the majority of the patients, the local SD of the deformation was slightly lager in the superior and inferior segments. Multiple regression analysis revealed that the anterior-posterior displacement of the CoG of the prostate had a highly significant correlation with the deformations in the middle-anterior (p < 0.01) and middle-posterior (p < 0.01) segments of the prostate surface (R2 = 0.84). However, there was no significant correlation between the displacement of the CoG and the deformation of the prostate surface in other segments.

Conclusion: Anterior-posterior displacement of the CoG of the prostate is highly correlated with deformation in its middle-anterior and posterior segments. In the radiation therapy for prostate cancer, it is necessary to optimize the internal margin for every position of the prostate measured using image-guided radiation therapy.

Citing Articles

Repeatability and reproducibility of prostate apparent diffusion coefficient values on a 1.5 T magnetic resonance linear accelerator.

Fernando N, Tadic T, Li W, Patel T, Padayachee J, Santiago A Phys Imaging Radiat Oncol. 2024; 30:100570.

PMID: 38544680 PMC: 10966090. DOI: 10.1016/j.phro.2024.100570.


Prostate stereotactic body radiotherapy: quantifying intra-fraction motion and calculating margins using the new BIR geometric uncertainties in daily online IGRT recommendations.

McNeice J, Sanilkumar N, Alexander S, Talbot J, Tree A, McNair H Br J Radiol. 2023; 96(1146):20220852.

PMID: 37001054 PMC: 10230383. DOI: 10.1259/bjr.20220852.


Prostate deformation during hypofractionated radiotherapy: an analysis of implanted fiducial marker displacement.

Knybel L, Cvek J, Blazek T, Binarova A, Parackova T, Resova K Radiat Oncol. 2021; 16(1):235.

PMID: 34876173 PMC: 8650520. DOI: 10.1186/s13014-021-01958-4.


Changes in apparent diffusion coefficient radiomics features during dose-painted radiotherapy and high dose rate brachytherapy for prostate cancer.

Lee S, Lee J, Craig T, Berlin A, Chung P, Menard C Phys Imaging Radiat Oncol. 2021; 9:1-6.

PMID: 33458419 PMC: 7807683. DOI: 10.1016/j.phro.2018.11.006.


Three-dimensional MRI evaluation of the effect of bladder volume on prostate translocation and distortion.

Snoj Z, Gill A, Rundo L, Sushentsev N, Barrett T Radiol Oncol. 2020; 54(1):48-56.

PMID: 31940289 PMC: 7087418. DOI: 10.2478/raon-2020-0001.


References
1.
Rodriguez-Vila B, Gaya F, Garcia-Vicente F, Gomez E . Three-dimensional quantitative evaluation method of nonrigid registration algorithms for adaptive radiotherapy. Med Phys. 2010; 37(3):1137-45. DOI: 10.1118/1.3302916. View

2.
Brock K . Results of a multi-institution deformable registration accuracy study (MIDRAS). Int J Radiat Oncol Biol Phys. 2009; 76(2):583-96. DOI: 10.1016/j.ijrobp.2009.06.031. View

3.
Wen N, Kumarasiri A, Nurushev T, Burmeister J, Xing L, Liu D . An assessment of PTV margin based on actual accumulated dose for prostate cancer radiotherapy. Phys Med Biol. 2013; 58(21):7733-44. PMC: 4073000. DOI: 10.1088/0031-9155/58/21/7733. View

4.
Zellars R, Roberson P, Strawderman M, Zhang D, Sandler H, Ten Haken R . Prostate position late in the course of external beam therapy: patterns and predictors. Int J Radiat Oncol Biol Phys. 2000; 47(3):655-60. DOI: 10.1016/s0360-3016(00)00469-7. View

5.
Wu J, Haycocks T, Alasti H, Ottewell G, Middlemiss N, Abdolell M . Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. Radiother Oncol. 2001; 61(2):127-33. DOI: 10.1016/s0167-8140(01)00452-2. View