» Articles » PMID: 26110181

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Overview
Date 2015 Jun 26
PMID 26110181
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years) with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible and that each screw passes through a plate without necessarily locking in.

Citing Articles

Number of screws in the articular segment of distal humerus AO/OTA C-type fractures treated with open reduction internal fixation is associated with complication rate.

Grogan B, Danford N, Lopez C, Maier 2nd S, Kongmalai P, Kovacevic D SICOT J. 2021; 7:25.

PMID: 33812466 PMC: 8019548. DOI: 10.1051/sicotj/2021006.


Development of three-dimensional preoperative planning system for the osteosynthesis of distal humerus fractures.

Yoshii Y, Teramura S, Oyama K, Ogawa T, Hara Y, Ishii T Biomed Eng Online. 2020; 19(1):56.

PMID: 32660498 PMC: 7359224. DOI: 10.1186/s12938-020-00801-3.


Biomechanical comparison of anatomical plating systems for comminuted distal humeral fractures.

Varady P, von Ruden C, Greinwald M, Hungerer S, Patzold R, Augat P Int Orthop. 2017; 41(9):1709-1714.

PMID: 28349182 DOI: 10.1007/s00264-017-3444-z.

References
1.
Maratt J, Peaks Y, Doro L, Karunakar M, Hughes R . An integer programming model for distal humerus fracture fixation planning. Comput Aided Surg. 2008; 13(3):139-47. DOI: 10.3109/10929080802057306. View

2.
Haidukewych G, Ricci W . Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg. 2008; 16(6):347-55. DOI: 10.5435/00124635-200806000-00007. View

3.
ODriscoll S . Optimizing stability in distal humeral fracture fixation. J Shoulder Elbow Surg. 2005; 14(1 Suppl S):186S-194S. DOI: 10.1016/j.jse.2004.09.033. View

4.
Ducrot G, Bonnomet F, Adam P, Ehlinger M . Treatment of distal humerus fractures with LCP DHP™ locking plates in patients older than 65 years. Orthop Traumatol Surg Res. 2013; 99(2):145-54. DOI: 10.1016/j.otsr.2012.12.011. View

5.
Ring D, Jupiter J . Fractures of the distal humerus. Orthop Clin North Am. 2000; 31(1):103-13. DOI: 10.1016/s0030-5898(05)70131-0. View