» Articles » PMID: 26091787

Temperature-based On-column Solute Focusing in Capillary Liquid Chromatography Reduces Peak Broadening from Pre-column Dispersion and Volume Overload when Used Alone or with Solvent-based Focusing

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2015 Jun 21
PMID 26091787
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis.

Citing Articles

[Research advances in nano liquid chromatography instrumentation].

Yang S, Li N, Ma Z, Tang T, Li T Se Pu. 2021; 39(10):1065-1076.

PMID: 34505428 PMC: 9404240. DOI: 10.3724/SP.J.1123.2021.06017.


Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods.

Ganesana M, Lee S, Wang Y, Venton B Anal Chem. 2017; 89(1):314-341.

PMID: 28105819 PMC: 5260807. DOI: 10.1021/acs.analchem.6b04278.


Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment.

Groskreutz S, Weber S J Chromatogr A. 2016; 1474:95-108.

PMID: 27836226 PMC: 5115952. DOI: 10.1016/j.chroma.2016.10.062.


Improving the Sensitivity, Resolution, and Peak Capacity of Gradient Elution in Capillary Liquid Chromatography with Large-Volume Injections by Using Temperature-Assisted On-Column Solute Focusing.

Wilson R, Groskreutz S, Weber S Anal Chem. 2016; 88(10):5112-21.

PMID: 27033165 PMC: 4940048. DOI: 10.1021/acs.analchem.5b04793.

References
1.
Desmet G, Eeltink S . Fundamentals for LC miniaturization. Anal Chem. 2012; 85(2):543-56. DOI: 10.1021/ac303317c. View

2.
Rupert A, Ou Y, Sandberg M, Weber S . Electroosmotic push-pull perfusion: description and application to qualitative analysis of the hydrolysis of exogenous galanin in organotypic hippocampal slice cultures. ACS Chem Neurosci. 2013; 4(5):838-48. PMC: 3656747. DOI: 10.1021/cn400082d. View

3.
Zhang J, Jaquins-Gerstl A, Nesbitt K, Rutan S, Michael A, Weber S . In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure. Anal Chem. 2013; 85(20):9889-97. PMC: 3899587. DOI: 10.1021/ac4023605. View

4.
Groskreutz S, Weber S . Temperature-assisted on-column solute focusing: a general method to reduce pre-column dispersion in capillary high performance liquid chromatography. J Chromatogr A. 2014; 1354:65-74. PMC: 4100596. DOI: 10.1016/j.chroma.2014.05.056. View

5.
Zhang J, Liu Y, Jaquins-Gerstl A, Shu Z, Michael A, Weber S . Optimization for speed and sensitivity in capillary high performance liquid chromatography. The importance of column diameter in online monitoring of serotonin by microdialysis. J Chromatogr A. 2012; 1251:54-62. PMC: 3419010. DOI: 10.1016/j.chroma.2012.06.002. View