» Articles » PMID: 2604057

Effect of Peripheral Electrical Stimulation on Measures of Tooth Pain Threshold and Oral Soft Tissue Comfort in Children

Overview
Journal Anesth Prog
Date 1989 Mar 1
PMID 2604057
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The effect of peripheral electrical stimulation on tooth pain threshold and comfort of oral soft tissue was evaluated in 30 children, using a double-blind, crossover, study design. Tooth pain threshold was measured before and after 8 minutes of electrical or sham stimulation. Comfort of oral soft tissue during placement of a rubber dam clamp was evaluated 3 minutes after electrical or sham stimulation was begun. Comfort level was rated by each subject and by the investigator, using a visual analog scale (VAS). Heart rate was measured before and immediately following placement of the clamp. Electrical stimulation significantly increased tooth pain threshold and reduced the cardiovascular stress response without altering comfort levels during placement of the clamp. These findings suggest that peripheral electrical stimulation applied in a pediatric dental setting alters sensory aspects of pain but not affective aspects of comfort.

Citing Articles

Reducing pain and discomfort associated with rubber dam clamp placement in children and adolescents: a systematic review and meta-analysis of effectiveness.

Afshari E, Sabbagh S, Khorakian F, Sarraf Shirazi A, Baghban A BMC Oral Health. 2023; 23(1):398.

PMID: 37328861 PMC: 10276393. DOI: 10.1186/s12903-023-03115-7.


Alternative practices of achieving anaesthesia for dental procedures: a review.

Angelo Z, Polyvios C J Dent Anesth Pain Med. 2018; 18(2):79-88.

PMID: 29744382 PMC: 5932994. DOI: 10.17245/jdapm.2018.18.2.79.


Transcutaneous electric nerve stimulation (TENS) in dentistry- A review.

Kasat V, Gupta A, Ladda R, Kathariya M, Saluja H, Farooqui A J Clin Exp Dent. 2015; 6(5):e562-8.

PMID: 25674327 PMC: 4312687. DOI: 10.4317/jced.51586.


Effect of electronic dental anesthesia on pain threshold and pain tolerance levels of human teeth subjected to stimulation with an electric pulp tester.

Gerschman J, Giebartowski J Anesth Prog. 1991; 38(2):45-9.

PMID: 1811428 PMC: 2148687.

References
1.
ANDERSSON S, Hansson G, Holmgren E, Renberg O . Evaluation of the pain suppressive effect of different frequencies of peripheral electrical stimulation in chronic pain conditions. Acta Orthop Scand. 1976; 47(2):149-57. DOI: 10.3109/17453677608989710. View

2.
Bakke M . Effect of acupuncture on the pain perception thresholds of human teeth. Scand J Dent Res. 1976; 84(6):404-8. DOI: 10.1111/j.1600-0722.1976.tb00514.x. View

3.
Engel B . Some physiological correlates of hunger and pain. J Exp Psychol. 1959; 57(6):389-96. DOI: 10.1037/h0039219. View

4.
Kajander K . Evaluation of low-intensity transcutaneous electrical nerve stimulation in combination with aspirin for reduction of controlled thermal sensation. Anesth Prog. 1988; 35(5):195-8. PMC: 2167860. View

5.
Brownbill J, Walker P, Bourcy B, Keenan K . Comparison of inferior dental nerve block injections in child patients using 30-gauge and 25-gauge short needles. Anesth Prog. 1987; 34(6):215-9. PMC: 2190042. View