» Articles » PMID: 26033981

Fundamentals in Clinical Coronary Physiology: Why Coronary Flow is More Important Than Coronary Pressure

Overview
Journal Eur Heart J
Date 2015 Jun 3
PMID 26033981
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

Wide attention for the appropriateness of coronary stenting in stable ischaemic heart disease (IHD) has increased interest in coronary physiology to guide decision making. For many, coronary physiology equals the measurement of coronary pressure to calculate the fractional flow reserve (FFR). While accumulating evidence supports the contention that FFR-guided revascularization is superior to revascularization based on coronary angiography, it is frequently overlooked that FFR is a coronary pressure-derived estimate of coronary flow impairment. It is not the same as the direct measures of coronary flow from which it was derived, and which are critical determinants of myocardial ischaemia. This review describes why coronary flow is physiologically and clinically more important than coronary pressure, details the resulting limitations and clinical consequences of FFR-guided clinical decision making, describes the scientific consequences of using FFR as a gold standard reference test, and discusses the potential of coronary flow to improve risk stratification and decision making in IHD.

Citing Articles

Feasibility and Safety of Post-Transcatheter Aortic Valve Replacement Coronary Revascularization Guided by Stress Cardiac Imaging.

Leclercq F, Akodad M, Prunet E, Huet F, Meunier P, Manna F J Clin Med. 2024; 13(19).

PMID: 39407992 PMC: 11478092. DOI: 10.3390/jcm13195932.


A Novel Method for Angiographic Contrast-Based Diagnosis of Stenosis in Coronary Artery Disease: In Vivo and In Vitro Analyses.

Kang W, Lee C, Kang G, Paeng D, Choi J Diagnostics (Basel). 2024; 14(13).

PMID: 39001319 PMC: 11241538. DOI: 10.3390/diagnostics14131429.


Impact of hyperaemic stenosis resistance on long-term outcomes of stable angina in the ILIAS Registry.

Boerhout C, Echavarria-Pinto M, de Waard G, Lee J, Mejia-Renteria H, Lee S EuroIntervention. 2024; 20(11):e699-e706.

PMID: 38840578 PMC: 11145309. DOI: 10.4244/EIJ-D-23-00713.


Application of physics-based flow models in cardiovascular medicine: Current practices and challenges.

Vardhan M, Randles A Biophys Rev (Melville). 2024; 2(1):011302.

PMID: 38505399 PMC: 10903374. DOI: 10.1063/5.0040315.


Noninvasive transthoracic doppler flow velocity and invasive thermodilution to assess coronary flow reserve.

Matsuda K, Hoshino M, Usui E, Hanyu Y, Sugiyama T, Kanaji Y Quant Imaging Med Surg. 2024; 14(1):421-431.

PMID: 38223097 PMC: 10784095. DOI: 10.21037/qims-23-416.