» Articles » PMID: 26019006

ROBucket: A Low Cost Operant Chamber Based on the Arduino Microcontroller

Overview
Publisher Springer
Specialty Social Sciences
Date 2015 May 29
PMID 26019006
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

The operant conditioning chamber is a cornerstone of animal behavioral research. Operant boxes are used to assess learning and motivational behavior in animals, particularly for food and drug reinforcers. However, commercial operant chambers cost several thousands of dollars. We have constructed the Rodent Operant Bucket (ROBucket), an inexpensive and easily assembled open-source operant chamber based on the Arduino microcontroller platform, which can be used to train mice to respond for sucrose solution or other liquid reinforcers. The apparatus contains two nose pokes, a drinking well, and a solenoid-controlled liquid delivery system. ROBucket can run fixed ratio and progressive ratio training schedules, and can be programmed to run more complicated behavioral paradigms. Additional features such as motion sensing and video tracking can be added to the operant chamber through the array of widely available Arduino-compatible sensors. The design files and programming code are open source and available online for others to use.

Citing Articles

A versatile and fast-sampling rate wearable analog data logger.

Bouchekioua Y, Matsui H, Watanabe S MethodsX. 2023; 10:102098.

PMID: 36950532 PMC: 10026020. DOI: 10.1016/j.mex.2023.102098.


GoFish: A low-cost, open-source platform for closed-loop behavioural experiments on fish.

Ajuwon V, Cruz B, Carrico P, Kacelnik A, Monteiro T Behav Res Methods. 2023; 56(1):318-329.

PMID: 36622558 PMC: 10794453. DOI: 10.3758/s13428-022-02049-2.


Gut microbiota suppress feeding induced by palatable foods.

Ousey J, Boktor J, Mazmanian S Curr Biol. 2022; 33(1):147-157.e7.

PMID: 36450285 PMC: 9839363. DOI: 10.1016/j.cub.2022.10.066.


Low-cost open hardware system for behavioural experiments simultaneously with electrophysiological recordings.

Aguiar L, de Vasconcelos N, Tunes G, Fontenele A, de Albuquerque Nogueira R, Bussotti Reyes M HardwareX. 2022; 8:e00132.

PMID: 35498270 PMC: 9041193. DOI: 10.1016/j.ohx.2020.e00132.


Custom-Built Operant Conditioning Setup for Calcium Imaging and Cognitive Testing in Freely Moving Mice.

Vassilev P, Fonseca E, Hernandez G, Pantoja-Urban A, Giroux M, Nouel D eNeuro. 2022; 9(1).

PMID: 35105659 PMC: 8856704. DOI: 10.1523/ENEURO.0430-21.2022.