Degradation of Alachlor Using an Enhanced Sono-Fenton Process with Efficient Fenton's Reagent Dosages
Overview
Toxicology
Authors
Affiliations
In this study, an enhanced sono-Fenton process for the degradation of alachlor is presented. At high ultrasonic power, low pH, and in the presence of adequate Fenton's reagent dosages, alachlor degradation can reach nearly 100%. The toxicity of treated alachlor wastewater, which was measured by changes in cell viability, slightly decreased after the Fenton or ultrasound/H2O2 process and significantly decreased after the enhanced sono-Fenton process. A satisfactory relationship was observed between the total organic carbon removal and cell viability increment, indicating that alachlor mineralization is a key step in reducing the toxicity of the solution. The formation of alachlor degradation byproducts was observed during the oxidation process, in which the first step was the substitution of a chloride by a hydroxyl group. In conclusion, the enhanced sono-Fenton process was effective in the degradation and detoxification of alachlor within a short reaction time. Thus, the treated wastewater can then be passed through a biological treatment unit for further treatment.
Preparation of low molecular weight heparin using an ultrasound-assisted Fenton-system.
Zhi Z, Li J, Chen J, Li S, Cheng H, Liu D Ultrason Sonochem. 2018; 52:184-192.
PMID: 30559077 PMC: 6475493. DOI: 10.1016/j.ultsonch.2018.11.016.