» Articles » PMID: 25977589

Evaluation of Particle Resuspension in Young Children's Breathing Zone Using Stationary and Robotic (PIPER) Aerosol Samplers

Overview
Journal J Aerosol Sci
Date 2015 May 16
PMID 25977589
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Development of asthma in young children may be associated with high exposure to particulate matter (PM). However, typical stationary samplers may not represent the personal exposure of children ages 3 and younger since they may not detect particles resuspended from the floor as children play, thus reducing our ability to correlate exposure and disease etiology. To address this, an autonomous robot, the Pretoddler Inhalable Particulate Environmental Robotic (PIPER) sampler, was developed to simulate the movements of children as they play on the floor. PIPER and a stationary sampler took simultaneous measurements of particle number concentration in six size channels using an optical particle counter and inhalable PM on filters in 65 homes in New Jersey, USA. To study particle resuspension, for each sampler we calculated the ratio of particle concentration measured while PIPER was moving to the average concentration of particles measured during a reference period when PIPER remained still. For all investigated particle sizes, higher particle resuspension was observed by PIPER compared to the stationary sampler. In 71% of carpeted homes a more significant (at the α = 0.05 level) resuspension of particles larger than 2.5 μm was observed by PIPER compared to the stationary sampler. Typically, particles larger than 2.5 μm were resuspended more efficiently than smaller particles, over both carpeted and bare floors. Additionally, in carpeted homes estimations of PM mass from the particle number concentrations measured on PIPER while it was moving were on average a factor of 1.54 higher compared to reference period when PIPER was not moving. For comparison, the stationary sampler measured an increase of PM mass by a factor of only 1.08 when PIPER was moving compared to a reference period. This demonstrates that PIPER is able to resuspend particles through movement, and provide a better characterization of the resuspended particles than stationary samplers. Accurate measurement of resuspended PM will improve estimates of children's total PM exposure.

Citing Articles

Resuspension of particles deposited by nano-enabled consumer sprays: The role of product type, flooring material, and resuspension force.

He R, Zhang J, Mainelis G Indoor Air. 2022; 32(11):e13157.

PMID: 36437654 PMC: 9827835. DOI: 10.1111/ina.13157.


A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses.

Parhizkar H, Fretz M, Laguerre A, Stenson J, Corsi R, Van Den Wymelenberg K J Expo Sci Environ Epidemiol. 2022; 33(3):339-346.

PMID: 36424424 PMC: 9686220. DOI: 10.1038/s41370-022-00499-6.


A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields.

Parhizkar H, Fretz M, Laguerre A, Stenson J, Corsi R, Van Den Wymelenberg K Res Sq. 2022; .

PMID: 35291299 PMC: 8923116. DOI: 10.21203/rs.3.rs-1437107/v2.


Pyrethroid levels in toddlers' breathing zone following a simulated indoor pesticide spray.

Zhou J, Mainelis G, Weisel C J Expo Sci Environ Epidemiol. 2018; 29(3):389-396.

PMID: 30185948 PMC: 7323485. DOI: 10.1038/s41370-018-0065-6.


Crawling-induced floor dust resuspension affects the microbiota of the infant breathing zone.

Hyytiainen H, Jayaprakash B, Kirjavainen P, Saari S, Holopainen R, Keskinen J Microbiome. 2018; 6(1):25.

PMID: 29394954 PMC: 5797336. DOI: 10.1186/s40168-018-0405-8.


References
1.
Moreno T, Querol X, Alastuey A, Viana M, Gibbons W . Profiling transient daytime peaks in urban air pollutants: city centre traffic hotspot versus urban background concentrations. J Environ Monit. 2009; 11(8):1535-42. DOI: 10.1039/b904844h. View

2.
Evans G, Peers A, Sabaliauskas K . Particle dose estimation from frying in residential settings. Indoor Air. 2009; 18(6):499-510. DOI: 10.1111/j.1600-0668.2008.00551.x. View

3.
Roberts J, Glass G, Mickelson L . A pilot study of the measurement and control of deep dust, surface dust, and lead in 10 old carpets using the 3-spot test while vacuuming. Arch Environ Contam Toxicol. 2005; 48(1):16-23. DOI: 10.1007/s00244-003-0224-0. View

4.
Jinot J, Bayard S . Respiratory health effects of passive smoking: EPA's weight-of-evidence analysis. J Clin Epidemiol. 1994; 47(4):339-49; discussion 351-3. DOI: 10.1016/0895-4356(94)90154-6. View

5.
Ferro A, Kopperud R, Hildemann L . Elevated personal exposure to particulate matter from human activities in a residence. J Expo Anal Environ Epidemiol. 2004; 14 Suppl 1:S34-40. DOI: 10.1038/sj.jea.7500356. View