Bacterial Contamination of Suction Catheter Tips During Aortic Valve Replacement Surgery: a Prospective Observational Cohort Study

Overview
Publisher Biomed Central
Date 2015 May 15
PMID 25972923
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Bacterial mediastinitis is a severe complication after open heart surgery. The infection causes prolonged hospitalization and an increased mortality risk. Observations from orthopaedic surgery showed that the suction catheter used during surgery is commonly contaminated with bacteria. The aim of this study was to describe the prevalence of suction catheter contamination in cardiac surgery and to study if suction time influences the contamination risk.

Methods: Fifty suction catheter tips were collected during 25 aortic valve replacement operations. The suction tip was exchanged once during the operation (after aortotomy closure). The tips were subjected to bacterial contamination analysis.

Results: In 20 of the 25 investigated cases (80%), bacterial contamination was detected on one or both tips. The tip used during the beginning of the operation showed bacterial contamination in 13/25 cases (52%) and the second tip in 12/25 (48%). In 5/25 cases (20%) both tips were contaminated. There was no association between bacterial contamination and suction time. Coagulase-negative staphylococcus was the most commonly detected microorganism.

Conclusions: The suction device should be considered as a potential source of bacterial contamination in cardiac surgery. The results suggest that the suction catheter should be replaced before key moments like valve implantation and sternal closure.

Citing Articles

Contamination Rate of Burnt Necrotic Tissue after Electrocoagulation in Total Knee Arthroplasty.

Rattanaprichavej P, Laoruengthana A, Galassi M, Weerakul S, Rasamimongkol S Clin Orthop Surg. 2020; 12(1):43-48.

PMID: 32117537 PMC: 7031428. DOI: 10.4055/cios.2020.12.1.43.

References
1.
Meals R, Knoke L . The surgical suction top--a contaminated instrument. J Bone Joint Surg Am. 1978; 60(3):409-10. View

2.
Gardlund B, Bitkover C, Vaage J . Postoperative mediastinitis in cardiac surgery - microbiology and pathogenesis. Eur J Cardiothorac Surg. 2002; 21(5):825-30. DOI: 10.1016/s1010-7940(02)00084-2. View

3.
Klareskov B . Bacteriologic contamination of suction tips during hip arthroplasty. Acta Orthop Scand. 1988; 59(4):410-1. DOI: 10.3109/17453678809149392. View

4.
Owens C, Stoessel K . Surgical site infections: epidemiology, microbiology and prevention. J Hosp Infect. 2008; 70 Suppl 2:3-10. DOI: 10.1016/S0195-6701(08)60017-1. View

5.
Robinson A, Drew S, Anderson J, Bentley G, Ridgway G . Suction tip contamination in the ultraclean-air operating theatre. Ann R Coll Surg Engl. 1993; 75(4):254-6. PMC: 2497922. View