Does Intraoperative Fluoroscopy Optimize Limb Length and the Precision of Acetabular Positioning in Primary THA?

Overview
Journal Orthopedics
Specialty Orthopedics
Date 2015 May 14
PMID 25970364
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Reduced limb length discrepancy and more accurate cup positioning are purported benefits of using fluoroscopy for total hip arthroplasty (THA). The authors compared limb length discrepancy and cup position in 200 patients (group I, posterior approach without fluoroscopy; group II, anterior supine approach with fluoroscopy) who underwent primary THA. Mean limb length discrepancy was 2.7 mm (SD, 5.2 mm; range, -9.8 to 20.9 mm) and 0.7 mm (SD, 3.7 mm; range, -11.8 to 10.5 mm) for groups I and II, respectively (P=.002). In group I, 7% of hips had limb length discrepancy greater than 1 cm compared with 3% in group II. Mean cup inclination measured 40.8° (SD, 5.0°; range, 26.1°-53.7°) in group I and 43.4° (SD, 5.6°; range, 31.3°-55.9°) in group II (P=.008). In group I, 96% of cups had inclination within 10° of the mean compared with 92% in group II (P=.24). Mean anteversion measured 35.3° (SD, 7.1°; range, 17.8°-60.7°) in group I and 25.9° (SD, 8.2°; range, 1.5°-44.8°) in group II (P=.0001). In group I, 87% of hips exhibited anteversion within 10° of the mean compared with 76% in group II (P=.045). Although the anterior approach with intraoperative fluoroscopy reduced mean limb length discrepancy, the clinical significance of this reduction is unclear. Fluoroscopy reduced the incidence of limb length discrepancy greater than 1 cm. However, the use of fluoroscopy did not help to improve the precision of cup positioning.

Citing Articles

Intraoperative Fluoroscopy Decreases Magnitude and Incidence of Leg-Length Discrepancy Following Total Hip Arthroplasty.

Blum C, Luzzi A, Frederick J, Cooper H, Shah R, Tatka J Arthroplast Today. 2025; 30:101492.

PMID: 39959375 PMC: 11827086. DOI: 10.1016/j.artd.2024.101492.


The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during total hip arthroplasty: A systematic review and meta-analysis.

Sun C, Gao H, Ma Q, Li H, Zhang X, Cai X Medicine (Baltimore). 2024; 103(37):e39528.

PMID: 39287287 PMC: 11404973. DOI: 10.1097/MD.0000000000039528.


Does Artificial Intelligence Outperform Humans Using Fluoroscopic-Assisted Computer Navigation for Total Hip Arthroplasty?.

Cardenas J, Gordon D, Waddell B, Kitziger K, Peters Jr P, Gladnick B Arthroplast Today. 2024; 27:101410.

PMID: 38840694 PMC: 11150909. DOI: 10.1016/j.artd.2024.101410.


The effect of intraoperative fluoroscopy on acetabular component positioning and patient anatomy restoration during posterior or posterolateral approach total hip arthroplasty: a meta-analysis.

Sun C, Lee W, Ma Q, Zhang X, Song F, Cai X Arch Orthop Trauma Surg. 2023; 144(4):1781-1792.

PMID: 38147077 DOI: 10.1007/s00402-023-05168-3.


Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position.

Chen P, Liu W, Wu C, Ruan P, Zeng J, Ji W BMC Musculoskelet Disord. 2023; 24(1):884.

PMID: 37957622 PMC: 10644644. DOI: 10.1186/s12891-023-07014-4.