» Articles » PMID: 25952405

Can CT Angiography Reconstructed from CT Perfusion Source Data on a 320-section Volume CT Scanner Replace Conventional CT Angiography for the Evaluation of Intracranial Arteries?

Overview
Journal Jpn J Radiol
Publisher Springer
Specialty Radiology
Date 2015 May 9
PMID 25952405
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare conventional CT angiography (CTA) and CTA reconstructed from CT perfusion source data (perfusion CTA) acquired on a 320-section CT scanner for the evaluation of intracranial arteries.

Materials And Methods: Our study included 7 patients who had undergone trapping of an intracranial aneurysm and placement of a bypass. All underwent conventional and perfusion CTA and digital subtraction angiography (DSA). Using DSA as the gold standard, 2 radiologists evaluated 10 arterial segments on conventional and perfusion CTA images. On a 4-point scale they independently scored the image quality and vascular visualization of the intracranial arteries on the conventional and perfusion CTA images. The effective radiation dose to each patient was also recorded.

Results: A total of 65 arterial segments without apparent abnormalities were assessed. While the mean image quality score tended to be slightly higher for conventional than perfusion CTA, there was no significant difference. The effective dose for perfusion and conventional CTA with unenhanced CT was 4.2 mSv and 3.1 mSv, respectively, for all patients.

Conclusion: For the evaluation of intracranial arteries using DSA as the gold standard, perfusion CTA yields image quality and vascular visualization similar to conventional CTA at an acceptable radiation dose.

Citing Articles

Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

Xiao Z, Zheng Y, Li J, Chen D, Liu F, Cao D Dentomaxillofac Radiol. 2017; 46(8):20170171.

PMID: 28845691 PMC: 5965941. DOI: 10.1259/dmfr.20170171.


Additive value of 320-section low-dose dynamic volume CT in relation to 3-T MRI for the preoperative evaluation of brain tumors.

Hayashida E, Hirai T, Nakamura H, Kidoh M, Azuma M, Iryo Y Jpn J Radiol. 2016; 34(10):691-699.

PMID: 27566608 DOI: 10.1007/s11604-016-0576-9.


Reduction of misregistration on cerebral four-dimensional computed tomography angiography images using advanced patient motion correction reconstruction.

Kunitomi Y, Watanabe Y, Arisawa A, Tsukabe A, Tanaka H, Takahashi H Jpn J Radiol. 2016; 34(9):605-10.

PMID: 27379502 DOI: 10.1007/s11604-016-0563-1.

References
1.
Siebert E, Bohner G, Dewey M, Masuhr F, Hoffmann K, Mews J . 320-slice CT neuroimaging: initial clinical experience and image quality evaluation. Br J Radiol. 2009; 82(979):561-70. DOI: 10.1259/bjr/27721218. View

2.
Ding B, Ling H, Chen K, Jiang H, Zhu Y . Comparison of cerebral blood volume and permeability in preoperative grading of intracranial glioma using CT perfusion imaging. Neuroradiology. 2006; 48(10):773-81. DOI: 10.1007/s00234-006-0120-1. View

3.
Hulme K, Rong J, Chasen B, Chuang H, Cody D, Wong F . A CT acquisition technique to generate images at various dose levels for prospective dose reduction studies. AJR Am J Roentgenol. 2011; 196(2):W144-51. DOI: 10.2214/AJR.10.4470. View

4.
Sanelli P, Jou A, Gold R, Reichman M, Greenberg E, John M . Using CT perfusion during the early baseline period in aneurysmal subarachnoid hemorrhage to assess for development of vasospasm. Neuroradiology. 2010; 53(6):425-34. PMC: 3118045. DOI: 10.1007/s00234-010-0752-z. View

5.
Ramli N, Rahmat K, Mah E, Waran V, Tan L, Chong H . Use of permeability surface area-product to differentiate intracranial tumours from abscess. Biomed Imaging Interv J. 2011; 5(1):e6. PMC: 3097750. DOI: 10.2349/biij.5.1.e6. View