» Articles » PMID: 25932359

Initial Experience with Use of Hydrogel Microcoils in Embolization of Pulmonary Arteriovenous Malformations

Overview
Journal Springerplus
Date 2015 May 2
PMID 25932359
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study is to describe our initial experience with embolization of pulmonary arteriovenous malformations (PAVMs) using hydrogel microcoils. The technical and radiological outcomes were retrospectively reviewed in seven patients with nine simple-type PAVMs (median feeder size 4 mm, range 3-6 mm) who underwent embolization. Hydrogel microcoils were mainly used, and detachable bare microcoils were combined as needed to occlude the terminal feeding artery just before the sac. Of a total of 43 microcoils, 30 (69.8%) hydrogel microcoils were deployed in eight PAVMs with the median number 3.5 (range 2 to 6) per lesion. All hydrogel microcoils were successfully deployed without microcatheter stuck or malposition. In the remaining one small PAVM, only soft bare microcoils were used, however, resulting in recanalization requiring additional coils in the second session. The venous sac was substantially shrunk in all lesions treated with hydrogel microcoils with the median size reduction rate 95.0% (range 81.8% to 99.0%) during the median follow-up period 10 months (range 6 to 18 months). In conclusion, hydrogel microcoils were safely and effectively applied for occluding PAVMs with relatively small feeders.

Citing Articles

Diagnosis and endovascular management of pulmonary arteriovenous malformations.

Kramdhari H, Valakkada J, Ayyappan A Br J Radiol. 2021; 94(1123):20200695.

PMID: 34038182 PMC: 8248199. DOI: 10.1259/bjr.20200695.


Usefulness of Hydrogel-Coated Coils in Embolization of Pulmonary Arteriovenous Malformations.

Shimohira M, Kawai T, Hashizume T, Muto M, Kitase M, Shibamoto Y Cardiovasc Intervent Radiol. 2018; 41(6):848-855.

PMID: 29344712 PMC: 5937894. DOI: 10.1007/s00270-018-1876-5.


Short-Segment Coil Embolization Using a Double-Balloon Technique in an Experimental Vascular Model.

Yunaiyama D, Saguchi T, Moriya T, Shirota N, Otaka J, Tokuuye K Cardiovasc Intervent Radiol. 2017; 40(8):1255-1260.

PMID: 28180927 PMC: 5489639. DOI: 10.1007/s00270-017-1589-1.

References
1.
Nambiar A, Bozlar U, Angle J, Jensen M, Hagspiel K . Initial clinical experience with biopolymer-coated detachable coils (HydroCoil) in peripheral embolization procedures. J Vasc Interv Radiol. 2008; 19(7):995-1001. DOI: 10.1016/j.jvir.2008.02.004. View

2.
Pollak J, Saluja S, Thabet A, Henderson K, Denbow N, White Jr R . Clinical and anatomic outcomes after embolotherapy of pulmonary arteriovenous malformations. J Vasc Interv Radiol. 2006; 17(1):35-44. DOI: 10.1097/01.RVI.0000191410.13974.B6. View

3.
Trerotola S, Pyeritz R . PAVM embolization: an update. AJR Am J Roentgenol. 2010; 195(4):837-45. DOI: 10.2214/AJR.10.5230. View

4.
Fidelman N, Gordon R, Bloom A, LaBerge J, Kerlan Jr R . Reperfusion of pulmonary arteriovenous malformations after successful embolotherapy with vascular plugs. J Vasc Interv Radiol. 2008; 19(8):1246-50. DOI: 10.1016/j.jvir.2008.05.001. View

5.
Maleux G, Deroose C, Fieuws S, Van Cutsem E, Heye S, Bosmans H . Prospective comparison of hydrogel-coated microcoils versus fibered platinum microcoils in the prophylactic embolization of the gastroduodenal artery before yttrium-90 radioembolization. J Vasc Interv Radiol. 2013; 24(6):797-803. DOI: 10.1016/j.jvir.2013.01.503. View