» Articles » PMID: 25883940

Biomaterial Hypersensitivity: is It Real? Supportive Evidence and Approach Considerations for Metal Allergic Patients Following Total Knee Arthroplasty

Overview
Journal Biomed Res Int
Publisher Wiley
Date 2015 Apr 18
PMID 25883940
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

The prospect of biomaterial hypersensitivity developing in response to joint implant materials was first presented more than 30 years ago. Many studies have established probable causation between first-generation metal-on-metal hip implants and hypersensitivity reactions. In a limited patient population, implant failure may ultimately be related to metal hypersensitivity. The examination of hypersensitivity reactions in current-generation metal-on-metal knee implants is comparatively limited. The purpose of this study is to summarize all available literature regarding biomaterial hypersensitivity after total knee arthroplasty, elucidate overall trends about this topic in the current literature, and provide a foundation for clinical approach considerations when biomaterial hypersensitivity is suspected.

Citing Articles

Comparison of hypoallergenic knee arthroplasties in patients with metal hypersensitivity versus standard arthroplasties in non-hypersensitivity patients: A scoping review.

Carulli C, Leggieri F, Roda D, Matassi F, Civinini R, Innocenti M J Orthop. 2025; 61:17-23.

PMID: 40046172 PMC: 11882338. DOI: 10.1016/j.jor.2024.09.015.


Comparative Study of Zirconium Nitride Multilayer Coatings: Crystallinity, In Vitro Oxidation Behaviour and Tribological Properties Deposited via Sputtering and Arc Deposition.

Dohm J, Schmidt S, Puente Reyna A, Richter B, Santana A, Grupp T J Funct Biomater. 2024; 15(8).

PMID: 39194662 PMC: 11355231. DOI: 10.3390/jfb15080223.


Hypoallergenic Knee Implant Usage and Clinical Outcomes: Are They Safe and Effective?.

Xie F, Sheng S, Ram V, Pandit H Arthroplast Today. 2024; 28:101399.

PMID: 39139362 PMC: 11320431. DOI: 10.1016/j.artd.2024.101399.


Increased Risk of New-Onset Rheumatoid Arthritis Among Osteoarthritis Patients Received Total Knee Arthroplasty: a global federated health network analysis.

Lin Z, Chang H, Wu Y, Gau S Int J Med Sci. 2024; 21(6):994-1002.

PMID: 38774753 PMC: 11103392. DOI: 10.7150/ijms.93457.


No difference in patient reported outcome and inflammatory response after coated and uncoated total knee arthroplasty - a randomized controlled study.

Tille E, Beyer F, Lutzner C, Postler A, Thomas P, Summer B BMC Musculoskelet Disord. 2023; 24(1):968.

PMID: 38098024 PMC: 10720193. DOI: 10.1186/s12891-023-07061-x.


References
1.
Basko-Plluska J, Thyssen J, Schalock P . Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis. 2011; 22(2):65-79. View

2.
Bergschmidt P, Bader R, Finze S, Schulze C, Kundt G, Mittelmeier W . Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating. Open Orthop J. 2011; 5:354-60. PMC: 3195852. DOI: 10.2174/1874325001105010354. View

3.
Park Y, Moon Y, Lim S, Yang J, Ahn G, Choi Y . Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005; 87(7):1515-21. DOI: 10.2106/JBJS.D.02641. View

4.
Cadosch D, Al-Mushaiqri M, Gautschi O, Meagher J, Simmen H, Filgueira L . Biocorrosion and uptake of titanium by human osteoclasts. J Biomed Mater Res A. 2010; 95(4):1004-10. DOI: 10.1002/jbm.a.32914. View

5.
Kieffer M . Nickel sensitivity: relationship between history and patch test reaction. Contact Dermatitis. 1979; 5(6):398-401. DOI: 10.1111/j.1600-0536.1979.tb04913.x. View