» Articles » PMID: 25873969

An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS

Overview
Journal Int J Anal Chem
Publisher Wiley
Specialty Chemistry
Date 2015 Apr 16
PMID 25873969
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r (2) = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL.

Citing Articles

Contributing to the management of viral infections through simple immunosensing of the arachidonic acid serum level.

Torrente-Rodriguez R, Ruiz-Valdepenas Montiel V, Iftimie S, Montero-Calle A, Pingarron J, Castro A Mikrochim Acta. 2024; 191(7):369.

PMID: 38834823 PMC: 11150294. DOI: 10.1007/s00604-024-06440-y.


Arachidonic Acid Metabolites of CYP450 Enzymes and HIF-1α Modulate Endothelium-Dependent Vasorelaxation in Sprague-Dawley Rats under Acute and Intermittent Hyperbaric Oxygenation.

Mihaljevic Z, Matic A, Stupin A, Frkanec R, Tavcar B, Kelava V Int J Mol Sci. 2020; 21(17).

PMID: 32883025 PMC: 7503979. DOI: 10.3390/ijms21176353.


Methods of the Analysis of Oxylipins in Biological Samples.

Liakh I, Pakiet A, Sledzinski T, Mika A Molecules. 2020; 25(2).

PMID: 31952163 PMC: 7024226. DOI: 10.3390/molecules25020349.


The Relevance of Mass Spectrometry Analysis for Personalized Medicine through Its Successful Application in Cancer "Omics".

Ciocan-Cartita C, Jurj A, Buse M, Gulei D, Braicu C, Raduly L Int J Mol Sci. 2019; 20(10).

PMID: 31130665 PMC: 6567119. DOI: 10.3390/ijms20102576.


Modern Methods of Sample Preparation for the Analysis of Oxylipins in Biological Samples.

Liakh I, Pakiet A, Sledzinski T, Mika A Molecules. 2019; 24(8).

PMID: 31027298 PMC: 6515351. DOI: 10.3390/molecules24081639.


References
1.
Wu S, Schoener D, Jemal M . Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of.... Rapid Commun Mass Spectrom. 2008; 22(18):2873-81. DOI: 10.1002/rcm.3680. View

2.
Xia Y, Jemal M . Phospholipids in liquid chromatography/mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association.... Rapid Commun Mass Spectrom. 2009; 23(14):2125-38. DOI: 10.1002/rcm.4121. View

3.
Fukaya T, Gondaira T, Kashiyae Y, Kotani S, Ishikura Y, Fujikawa S . Arachidonic acid preserves hippocampal neuron membrane fluidity in senescent rats. Neurobiol Aging. 2006; 28(8):1179-86. DOI: 10.1016/j.neurobiolaging.2006.05.023. View

4.
Watt A, Morrison D, Locker K, Evans D . Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS. Anal Chem. 2000; 72(5):979-84. DOI: 10.1021/ac9906633. View

5.
KING R, Bonfiglio R, Fernandez-Metzler C, Miller-Stein C, Olah T . Mechanistic investigation of ionization suppression in electrospray ionization. J Am Soc Mass Spectrom. 2000; 11(11):942-50. DOI: 10.1016/S1044-0305(00)00163-X. View