» Articles » PMID: 25861907

Endocuff-assisted Colonoscopy Increases Polyp Detection Rate: a Simulated Randomized Study Involving an Anatomic Colorectal Model and 32 International Endoscopists

Overview
Journal Surg Endosc
Publisher Springer
Date 2015 Apr 12
PMID 25861907
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The undetected colonic lesions behind the folds and flexures are a major factor contributing to the adenoma miss rate.

Objective: To assess the efficacy of Endocuff, a special attachment was fixed at the distal tip of a colonoscope, for the polyp detection. This soft accessory is composed of a plastic cap surrounded by flexible finger-like projections on the lateral sides of the cap that make holding of the folds during scope withdrawal easier.

Design: This was a simulated pilot study with one anatomic colorectal model, containing 13 polyps positioned in obvious locations and behind the folds. Thirty-two endoscopists (16 Japanese and 16 foreign visitors) with different levels of experience performed examinations on the model in a randomized order by using Endocuff-assisted colonoscopy (EAC) and standard colonoscope (SC).

Main Outcome Measurements: To assess the detection rate of polyps and the feasibility of Endocuff insertion.

Results: EAC detected significantly more polyps than SC with 9.9 versus 7.5 mean lesions (p = 0.03), respectively, comparing the 16 first colonoscopies in each group. Endocuff was useful independent of the level of experience of the participants. After crossover, EAC in second position allowed an additional detection of 1.8 polyps compared with SC (p = 0.001). After adjustment on experience, time of detection, and order of colonoscopy, EAC over-detected 1.2 polyps (p = 0.0037). The insertion time (p = 0.99) was identical. There was no difference in the mean time of polyp detection between EAC and SC groups (p = 0.520).

Limitations: This was not a clinical study. The stiffness of the folds in the colonic model was higher than in the human large bowel.

Conclusion: EAC was associated with a higher polyp detection rate. Even in such relatively stiff anatomic model, it was easier to spread out the colonic mucosa between the folds using this cap. This study provides an additional argument for the routine application of this easy-to-use accessory to improve polyp detection.

Citing Articles

Endocuff Vision-Assisted Resection for Difficult Colonic Lesions-Preliminary Results of a Multicenter, Prospective Randomized Pilot Study.

Palma R, Andrisani G, Fanello G, Lauro A, Panetta C, Eberspacher C J Clin Med. 2023; 12(15).

PMID: 37568382 PMC: 10420096. DOI: 10.3390/jcm12154980.


Endocuff-Assisted versus Cap-Assisted Colonoscopy Performed by Trainees: A Retrospective Study.

Okagawa Y, Sumiyoshi T, Tomita Y, Oiwa S, Ogata F, Jin T Clin Endosc. 2020; 53(3):339-345.

PMID: 31918537 PMC: 7280843. DOI: 10.5946/ce.2019.124.


Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study.

Ratone J, Bories E, Caillol F, Pesenti C, Godat S, Sellier F Ann Gastroenterol. 2017; 30(5):512-517.

PMID: 28845106 PMC: 5566771. DOI: 10.20524/aog.2017.0176.


New device to implement the adenoma detection rate.

Zippi M, Hong W, Crispino P, Traversa G World J Clin Cases. 2017; 5(7):258-263.

PMID: 28798920 PMC: 5535316. DOI: 10.12998/wjcc.v5.i7.258.


Advances in image enhancement in colonoscopy for detection of adenomas.

Matsuda T, Ono A, Sekiguchi M, Fujii T, Saito Y Nat Rev Gastroenterol Hepatol. 2017; 14(5):305-314.

PMID: 28293023 DOI: 10.1038/nrgastro.2017.18.


References
1.
Gralnek I, Segol O, Suissa A, Siersema P, Carr-Locke D, Halpern Z . A prospective cohort study evaluating a novel colonoscopy platform featuring full-spectrum endoscopy. Endoscopy. 2013; 45(9):697-702. DOI: 10.1055/s-0033-1344395. View

2.
Biecker E, Floer M, Heinecke A, Strobel P, Bohme R, Schepke M . Novel endocuff-assisted colonoscopy significantly increases the polyp detection rate: a randomized controlled trial. J Clin Gastroenterol. 2014; 49(5):413-8. DOI: 10.1097/MCG.0000000000000166. View

3.
Triadafilopoulos G, Watts H, Higgins J, Dam J . A novel retrograde-viewing auxiliary imaging device (Third Eye Retroscope) improves the detection of simulated polyps in anatomic models of the colon. Gastrointest Endosc. 2006; 65(1):139-44. DOI: 10.1016/j.gie.2006.07.044. View

4.
DeMarco D, Odstrcil E, Lara L, Bass D, Herdman C, Kinney T . Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group. Gastrointest Endosc. 2010; 71(3):542-50. DOI: 10.1016/j.gie.2009.12.021. View

5.
Matsushita M, HAJIRO K, Okazaki K, Takakuwa H, Tominaga M . Efficacy of total colonoscopy with a transparent cap in comparison with colonoscopy without the cap. Endoscopy. 1998; 30(5):444-7. DOI: 10.1055/s-2007-1001305. View