» Articles » PMID: 25820886

The Capsular Ligaments Provide More Hip Rotational Restraint Than the Acetabular Labrum and the Ligamentum Teres : an Experimental Study

Overview
Journal Bone Joint J
Date 2015 Mar 31
PMID 25820886
Citations 44
Authors
Affiliations
Soon will be listed here.
Abstract

In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty.

Citing Articles

Total Hip Arthroplasty Using the Conjoined Tendon-Preserving Posterior Approach: The Modified Posterior Approach with a Minimum of 2-Year Follow-Up.

Ozawa Y, Osawa Y, Seki T, Takegami Y, Iida H, Funahashi H Orthop Surg. 2024; 17(1):53-61.

PMID: 39600103 PMC: 11735358. DOI: 10.1111/os.14194.


Contribution of the Medial Iliofemoral Ligament to Hip Stability After Total Hip Arthroplasty Through the Direct Anterior Approach.

Bido J, Meyers K, Gonzalez F, Zigan C, Wright T, Rodriguez J J Arthroplasty. 2024; 39(9S1):S266-S271.

PMID: 38537838 PMC: 11330729. DOI: 10.1016/j.arth.2024.03.044.


Contributions of the Abductor Muscles to Rotational and Distractive Stability of the Hip in a Biomechanical Cadaveric Model.

Lim D, Lazaro L, Kyhos J, Chau M, Ladnier K, Nelson T Orthop J Sports Med. 2024; 12(3):23259671241231984.

PMID: 38444567 PMC: 10913509. DOI: 10.1177/23259671241231984.


In vivo interrelationships between the gluteus minimus and hip joint capsule in the hip internal rotation position with flexion.

Tsutsumi M, Saiki A, Yamaguchi I, Nimura A, Utsunomiya H, Akita K BMC Musculoskelet Disord. 2024; 25(1):87.

PMID: 38263079 PMC: 10804474. DOI: 10.1186/s12891-024-07188-5.


Instantaneous Generation of Subject-Specific Finite Element Models of the Hip Capsule.

Anantha-Krishnan A, Myers C, Fitzpatrick C, Clary C Bioengineering (Basel). 2024; 11(1).

PMID: 38247914 PMC: 10813259. DOI: 10.3390/bioengineering11010037.


References
1.
Austin D, Horneff 3rd J, Kelly 4th J . Anterior hip dislocation 5 months after hip arthroscopy. Arthroscopy. 2014; 30(10):1380-2. DOI: 10.1016/j.arthro.2014.04.099. View

2.
Nadzadi M, Pedersen D, Yack H, Callaghan J, Brown T . Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech. 2003; 36(4):577-91. DOI: 10.1016/s0021-9290(02)00232-4. View

3.
Van Arkel R, Modenese L, Phillips A, Jeffers J . Hip abduction can prevent posterior edge loading of hip replacements. J Orthop Res. 2013; 31(8):1172-9. PMC: 3736148. DOI: 10.1002/jor.22364. View

4.
de Haan R, Campbell P, Su E, De Smet K . Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br. 2008; 90(9):1158-63. DOI: 10.1302/0301-620X.90B9.19891. View

5.
Myers C, Register B, Lertwanich P, Ejnisman L, Pennington W, Giphart J . Role of the acetabular labrum and the iliofemoral ligament in hip stability: an in vitro biplane fluoroscopy study. Am J Sports Med. 2011; 39 Suppl:85S-91S. DOI: 10.1177/0363546511412161. View