Velocity Valleys Enable Efficient Capture and Spatial Sorting of Nanoparticle-bound Cancer Cells
Overview
Affiliations
The development of strategies for isolating rare cells from complex matrices like blood is important for a wide variety of applications including the analysis of bloodborne cancer cells, infectious pathogens, and prenatal testing. Due to their high colloidal stability and surface-to-volume ratio, antibody-coated magnetic nanoparticles are excellent labels for cellular surface markers. Unfortunately, capture of nanoparticle-bound cells at practical flow rates is challenging due to the small volume, and thus low magnetic susceptibility, of magnetic nanoparticles. We have developed a means to capture nanoparticle-labeled cells using microstructures which create pockets of locally low linear velocity, termed velocity valleys. Cells that enter a velocity valley slow down momentarily, allowing the magnetic force to overcome the reduced drag force and trap the cells. Here, we describe a model for this mechanism of cell capture and use this model to guide the rational design of a device that efficiently captures rare cells and sorts them according to surface expression in complex matrices with greater than 10,000-fold specificity. By analysing the magnetic and drag forces on a cell, we calculate a threshold linear velocity for capture and relate this to the capture efficiency. We find that the addition of X-shaped microstructures enhances capture efficiency 5-fold compared to circular posts. By tuning the linear velocity, we capture cells with a 100-fold range of surface marker expression with near 100% efficiency and sort these cells into spatially distinct zones. By tuning the flow channel geometry, we reduce non-specific cell adhesion by 5-fold.
Advances in microfluidic platforms for tumor cell phenotyping: from bench to bedside.
Joshi R, Ahmadi H, Gardner K, Bright R, Wang W, Li W Lab Chip. 2025; 25(5):856-883.
PMID: 39774602 PMC: 11859771. DOI: 10.1039/d4lc00403e.
Descamps L, Le Roy D, Deman A Int J Mol Sci. 2022; 23(4).
PMID: 35216097 PMC: 8875744. DOI: 10.3390/ijms23041981.
High-Throughput Cell Trapping in the Dentate Spiral Microfluidic Channel.
Lu J, Dai B, Wang K, Long Y, Yang Z, Chen J Micromachines (Basel). 2021; 12(3).
PMID: 33803303 PMC: 8000121. DOI: 10.3390/mi12030288.
Williams P, Moore L, Joshi P, Goodin M, Zborowski M, Fleischman A J Chromatogr A. 2021; 1637:461823.
PMID: 33385746 PMC: 7827554. DOI: 10.1016/j.chroma.2020.461823.
Nanotechnology-Assisted Isolation and Analysis of Circulating Tumor Cells on Microfluidic Devices.
Cheng J, Liu Y, Zhao Y, Zhang L, Zhang L, Mao H Micromachines (Basel). 2020; 11(8).
PMID: 32823926 PMC: 7465711. DOI: 10.3390/mi11080774.