Gastric Perforation Following Endoscopic Removal of a Bravo PH Capsule in a Cat
Overview
Affiliations
A 7-year-old domestic shorthair cat was evaluated for hyporexia and weight loss following endoscopic placement of an intragastric pH monitoring device. Physical examination of the cat was unremarkable, and its blood work was notable for a mild hypoalbuminemia. The cat's acute hyporexia and weight loss was attributed to discomfort associated with the intragastric pH monitoring device, as has been reported in humans. Endoscopic removal of the intragastric pH monitoring device resulted in gastric perforation. The cat underwent exploratory laparotomy for surgical resection and repair of the perforated area. To our knowledge, this is the first report of gastric perforation secondary to removal of a Bravo pH capsule. Caution may be advised when considering intragastric pH capsule removal in cats.
Medical management of gastrinoma in a cat.
Lane M, Larson J, Hecht S, Tolbert M JFMS Open Rep. 2017; 2(1):2055116916646389.
PMID: 28491421 PMC: 5362883. DOI: 10.1177/2055116916646389.
Sutalo S, Ruetten M, Hartnack S, Reusch C, Kook P J Vet Intern Med. 2015; 29(3):840-6.
PMID: 25966746 PMC: 4895399. DOI: 10.1111/jvim.12580.