The Relationship Between Heart-carotid Pulse Transit Time and Carotid Intima-media Thickness in Hypertensive Patients

Overview
Journal J Hum Hypertens
Date 2015 Mar 13
PMID 25761666
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The study aimed to investigate the relationship between heart-carotid pulse transit time and carotid intima-media thickness (CIMT) in hypertensive patients, and whether including the pre-ejection period (PEP) in heart-carotid pulse transit time would affect this correlation. A total of 62 hypertensive patients were included in this study. They were divided into the normal CIMT group (n=33, CIMT⩽0.8 mm) and the thickened CIMT group (n=29, CIMT>0.8 mm). The noninvasive ultrasound method was used to measure CIMT, electrocardiogram R-wave-based heart-carotid pulse transit time (rcPTT) and PEP. Aortic valve-carotid artery pulse transit time (acPTT) was calculated by subtracting PEP from rcPTT. Simple linear analysis showed that CIMT was negatively associated with rcPTT and acPTT (r=-0.57, P<0.0001; r=-0.41, P=0.016) in the normal CIMT group as well as in the thickened CIMT group (r=-0.50, P=0.0053; r=-0.59, P=0.001). These relationships were eliminated in the normal CIMT group after adjusting for age, gender, smoking behaviour, systolic blood pressure, diastolic blood pressure and cholesterol levels. However, rcPTT and acPTT still showed significant correlations with CIMT in the thickened CIMT group. In conclusion, rcPTT and acPTT were associated with CIMT, independent of well-known clinical confounders in thickened CIMT hypertensive patients. Therefore, rcPTT and acPTT might be useful markers for atherosclerosis evaluation.

Citing Articles

Research and development of the pulse acquisition system and the pulse biomimetic reproduction system.

Kai Y, Yunjing M, Shen G, Heng L, Bin X J Tradit Chin Med. 2025; 45(1):213-220.

PMID: 39957176 PMC: 11764930. DOI: 10.19852/j.cnki.jtcm.2025.01.021.


Association between mental illness and blood pressure variability: a systematic review.

Shahimi N, Lim R, Mat S, Goh C, Tan M, Lim E Biomed Eng Online. 2022; 21(1):19.

PMID: 35313918 PMC: 8935841. DOI: 10.1186/s12938-022-00985-w.


Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar.

Park J, Lee Y, Choi Y, Heo R, Park H, Cho S Sci Rep. 2019; 9(1):11892.

PMID: 31417149 PMC: 6695386. DOI: 10.1038/s41598-019-48386-9.


A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms.

Yang T, Jo G, Koo J, Woo S, Kim J, Kim Y Biomed Eng Online. 2019; 18(1):1.

PMID: 30602383 PMC: 6317228. DOI: 10.1186/s12938-018-0620-3.


Heart-Carotid Pulse Wave Velocity a Useful Index of Atherosclerosis in Chinese Hypertensive Patients.

Li C, Xiong H, Pirbhulal S, Wu D, Li Z, Huang W Medicine (Baltimore). 2015; 94(51):e2343.

PMID: 26705228 PMC: 4697994. DOI: 10.1097/MD.0000000000002343.

References
1.
Wong M, Pickwell-MacPherson E, Zhang Y, Cheng J . The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time technique. Eur J Appl Physiol. 2010; 111(1):135-44. DOI: 10.1007/s00421-010-1626-0. View

2.
OLeary D, Polak J, Kronmal R, Savage P, Borhani N, Kittner S . Thickening of the carotid wall. A marker for atherosclerosis in the elderly? Cardiovascular Health Study Collaborative Research Group. Stroke. 1996; 27(2):224-31. DOI: 10.1161/01.str.27.2.224. View

3.
RILEY W, Evans G, Sharrett A, Burke G, BARNES R . Variation of common carotid artery elasticity with intimal-medial thickness: the ARIC Study. Atherosclerosis Risk in Communities. Ultrasound Med Biol. 1997; 23(2):157-64. DOI: 10.1016/s0301-5629(96)00211-6. View

4.
Lim T, Lim E, Dwivedi G, Kooner J, Senior R . Normal value of carotid intima-media thickness--a surrogate marker of atherosclerosis: quantitative assessment by B-mode carotid ultrasound. J Am Soc Echocardiogr. 2007; 21(2):112-6. DOI: 10.1016/j.echo.2007.05.002. View

5.
Jiang B, Liu B, McNeill K, Chowienczyk P . Measurement of pulse wave velocity using pulse wave Doppler ultrasound: comparison with arterial tonometry. Ultrasound Med Biol. 2007; 34(3):509-12. DOI: 10.1016/j.ultrasmedbio.2007.09.008. View