A Reliable and Valid Questionnaire Was Developed to Measure Computer Vision Syndrome at the Workplace
Overview
Affiliations
Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace.
Study Design And Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ).
Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839).
Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.
Computer vision syndrome: a comprehensive literature review.
Kahal F, Al Darra A, Torbey A Future Sci OA. 2025; 11(1):2476923.
PMID: 40055942 PMC: 11901492. DOI: 10.1080/20565623.2025.2476923.
Hecht K, Marwah M, Wood V, Nishida Y, Bach A, Gerson J Adv Ther. 2025; .
PMID: 40014233 DOI: 10.1007/s12325-025-03125-7.
Lopresti A, Smith S Front Nutr. 2025; 12:1522302.
PMID: 39963662 PMC: 11830589. DOI: 10.3389/fnut.2025.1522302.
Performance of a Toric, Monthly, Soft Contact Lens in Digital Device Users.
Pucker A, Franklin Q, Perkins A, May K, Kannarr S, Bromley M Clin Optom (Auckl). 2025; 17:11-20.
PMID: 39867134 PMC: 11761843. DOI: 10.2147/OPTO.S505701.
Is the convergence insufficiency symptom survey applicable to elderly individuals?.
Abdi S, Kangari H, Rahmani S, Baghban A, Kamary Rad Z BMC Ophthalmol. 2025; 25(1):28.
PMID: 39825318 PMC: 11742225. DOI: 10.1186/s12886-025-03857-8.