» Articles » PMID: 25741201

Ultrasound-guided Fine Needle Aspiration of Thyroid Nodules: a Consensus Statement by the Korean Society of Thyroid Radiology

Overview
Journal Korean J Radiol
Specialty Radiology
Date 2015 Mar 6
PMID 25741201
Citations 69
Authors
Affiliations
Soon will be listed here.
Abstract

Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

Citing Articles

Safety and Efficacy of Ultrasound-Guided Thrombin Injection for Pseudoaneurysms Arising after Ultrasound-Guided Biopsy of Thyroid Nodules.

Ham T, Lee J, Jeon Y, Choi K, Hwang I, Yoo R AJNR Am J Neuroradiol. 2024; 46(1):166-169.

PMID: 39510805 PMC: 11735430. DOI: 10.3174/ajnr.A8428.


Fine-Needle Aspiration versus the CytoCore® Motorized Rotating Needle Device for Thyroid Nodule Biopsies: A Retrospective Cohort Study.

Verma A, McDowell R, Porreca A Acta Cytol. 2024; 68(5):405-412.

PMID: 39265559 PMC: 11548101. DOI: 10.1159/000541374.


Combining radiomics and molecular biomarkers: a novel economic tool to improve diagnostic ability in papillary thyroid cancer.

Wang Q, Dai L, Lin S, Zhang S, Wen J, Chen E Front Endocrinol (Lausanne). 2024; 15:1378360.

PMID: 39205691 PMC: 11349561. DOI: 10.3389/fendo.2024.1378360.


Needle size for thyroid fine needle aspiration cytology. A single institution experience.

Cianci P, Tumolo R, Conversano I, Travaglia D, Trigiante G, Lantone G Front Surg. 2024; 11:1368614.

PMID: 39035112 PMC: 11258859. DOI: 10.3389/fsurg.2024.1368614.


Artificial intelligence in screening and diagnosis of surgical diseases: A narrative review.

Palomba G, Fernicola A, Della Corte M, Capuano M, De Palma G, Aprea G AIMS Public Health. 2024; 11(2):557-576.

PMID: 39027395 PMC: 11252578. DOI: 10.3934/publichealth.2024028.


References
1.
Kwak J, Jung I, Baek J, Baek S, Choi N, Choi Y . Image reporting and characterization system for ultrasound features of thyroid nodules: multicentric Korean retrospective study. Korean J Radiol. 2013; 14(1):110-7. PMC: 3542293. DOI: 10.3348/kjr.2013.14.1.110. View

2.
Tublin M, Martin J, Rollin L, Pealer K, Kurs-Lasky M, Ohori N . Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter?. J Ultrasound Med. 2007; 26(12):1697-701. DOI: 10.7863/jum.2007.26.12.1697. View

3.
Ceresini G, Corcione L, Morganti S, Milli B, Bertone L, Prampolini R . Ultrasound-guided fine-needle capillary biopsy of thyroid nodules, coupled with on-site cytologic review, improves results. Thyroid. 2004; 14(5):385-9. DOI: 10.1089/105072504774193230. View

4.
Lubitz C, Nagarkatti S, Faquin W, Samir A, Hassan M, Barbesino G . Diagnostic yield of nondiagnostic thyroid nodules is not altered by timing of repeat biopsy. Thyroid. 2012; 22(6):590-4. PMC: 3733136. DOI: 10.1089/thy.2011.0442. View

5.
Redman R, Zalaznick H, Mazzaferri E, Massoll N . The impact of assessing specimen adequacy and number of needle passes for fine-needle aspiration biopsy of thyroid nodules. Thyroid. 2006; 16(1):55-60. DOI: 10.1089/thy.2006.16.55. View