» Articles » PMID: 25734468

Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography

Overview
Specialty Radiology
Date 2015 Mar 4
PMID 25734468
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare standard of care and reduced dose (RD) abdominal computed tomography (CT) images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR) techniques.

Materials And Methods: In an Institutional Review Board-approved, prospective clinical study, 28 patients (mean age 59 ± 13 years ), undergoing clinically indicated routine abdominal CT on a 64-channel multi-detector CT scanner, gave written informed consent for acquisition of an additional RD (<1 milli-Sievert) abdomen CT series. Sinogram data of RD series were reconstructed with FBP, ASIR, and MBIR and compared with FBP images of standard dose abdomen CT. Two radiologists performed randomized, independent, and blinded comparison for lesion detection, lesion margin, visibility of normal structures, and diagnostic confidence.

Results: Mean CT dose index volume was 10 ± 3.4 mGy and 1.3 ± 0.3 mGy for standard and RD CT, respectively. There were 73 "true positive" lesions detected on standard of care CT. Nine lesions (<8 mm in size) were missed on RD abdominal CT images which included liver lesions, liver cysts, kidney cysts, and paracolonic abscess. These lesions were missed regardless of patient size and types of iterative reconstruction techniques used for reconstruction of RD data sets. The visibility of lesion margin was suboptimal in (23/28) patients with RD FBP, (15/28) patients with RD ASIR, and (14/28) patients with RD MBIR compared to standard of care FBP images (P < 0.001). Diagnostic confidence for the assessment of lesions on RD images was suboptimal in most patients regardless of iterative reconstruction techniques.

Conclusions: Clinically significant lesions (< 8 mm) can be missed on abdominal CT examinations acquired at a CT dose index volume of 1.3 mGy regardless of patients' size and reconstruction techniques (FBP, ASIR, and MBIR).

Citing Articles

Low-dose abdominopelvic computed tomography in patients with lymphoma: An image quality and radiation dose reduction study.

Yoon S, Yoo K, Park S, Kim H, Lee J, Park J PLoS One. 2022; 17(8):e0272356.

PMID: 35951525 PMC: 9371255. DOI: 10.1371/journal.pone.0272356.


CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction.

Wellenberg R, A C van Osch J, Boelhouwers H, Edens M, Streekstra G, Ettema H Skeletal Radiol. 2019; 48(11):1775-1785.

PMID: 31016340 PMC: 6776565. DOI: 10.1007/s00256-019-03206-z.


Application value of iterative reconstruction with CTA to intractable headache patients.

Xu Y, Yu S, Zhang L, Zheng J, Chen Y, Che Y Exp Ther Med. 2018; 16(2):603-608.

PMID: 30112026 PMC: 6090427. DOI: 10.3892/etm.2018.6232.


The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose.

Feng C, Zhu D, Zou X, Li A, Hu X, Li Z Medicine (Baltimore). 2018; 97(12):e0151.

PMID: 29561422 PMC: 5895339. DOI: 10.1097/MD.0000000000010151.


Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility.

Midya A, Chakraborty J, Gonen M, Do R, Simpson A J Med Imaging (Bellingham). 2018; 5(1):011020.

PMID: 29487877 PMC: 5812985. DOI: 10.1117/1.JMI.5.1.011020.