» Articles » PMID: 25729583

Bacteriological Quality of Effluent Submitted Consecutively to a Macrofiltration and Ultraviolet Light Systems in the Tunisian Conditions

Overview
Publisher Springer
Date 2015 Mar 3
PMID 25729583
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

This paper deals with the study of bacteriological quality of effluents that have undergone consecutively different macrofiltration system (pressure sand filter or disc filter used as a secondary treatment) and UV254 irradiation process (used as a tertiary treatment). These two successive systems of treatment were evaluated to determine their possible application as commonly alternatives to the conventional system of wastewater treatment and disinfection before wastewater reuse. They both combined systems of wastewater treatment released effluent of excellent bacteriological quality, with almost total absence of feacal coliforms, of E. coli and of P. aeruginosa). However, if the bacteriological quality of the effluent remained constant in the case of macrofiltration system (disc filter or pressure sand filter); the UV disinfection process showed to deeply depend on the quality of effluent, particularly with regard to UV transmittance. The daily bacteriological monitoring of the secondary effluent at the exit of the pressure sand filter by UV reactor and by using a dose of 96 mJ/cm(2), corresponding to an exposure of 16 min, showed an average rate of inactivation of around 3 U-Log, for feacal coliforms, E. coli and P. aeruginosa, respectively. Therefore, the average bacterial concentration remaining in the water at the exit of the UV reactor is less than 1000 cfu/100 ml for feacal coliform and E. coli. For P. aeruginosa, the remaining number is less than 100 bacteria/100 ml. These two last values coincide substantially with the range recommended by several standardized international guidelines. Therefore, numerous authors reported that P. aeruginosa is very resistant to UV irradiation compared to the other bacterial indicators. In contrast, our study revealed that feacal coliforms and E. coli were more UV light resistant than P. aeruginosa. This finding could be explained by the fact that E. coli and feacal coliform forms aggregates in the treated effluent, while P. aeruginosa exists either as discrete cells or as cell pairs.

Citing Articles

The response of aggregated Pseudomonas putida CP1 cells to UV-C and UV-A/B disinfection.

Maganha de Almeida A, Quilty B World J Microbiol Biotechnol. 2016; 32(11):185.

PMID: 27655528 DOI: 10.1007/s11274-016-2138-9.


Modeling and kinetic characterization of wastewater disinfection using chlorine and UV irradiation.

Mounaouer B, Abdennaceur H Environ Sci Pollut Res Int. 2016; 23(19):19861-75.

PMID: 27421857 DOI: 10.1007/s11356-016-7173-4.

References
1.
Marcucci M, Ciabatti I, Matteucci A, Vernaglione G . Membrane technologies applied to textile wastewater treatment. Ann N Y Acad Sci. 2003; 984:53-64. DOI: 10.1111/j.1749-6632.2003.tb05992.x. View

2.
Gilboa Y, Friedler E . UV disinfection of RBC-treated light greywater effluent: kinetics, survival and regrowth of selected microorganisms. Water Res. 2007; 42(4-5):1043-50. DOI: 10.1016/j.watres.2007.09.027. View

3.
Brahmi M, Belhadi N, Hamdi H, Hassen A . Modeling of secondary treated wastewater disinfection by UV irradiation: effects of suspended solids content. J Environ Sci (China). 2010; 22(8):1218-24. DOI: 10.1016/s1001-0742(09)60241-2. View

4.
Highsmith A, Abshire R . Evaluation of a most-probable-number technique for the enumeration of Pseudomonas aeruginosa. Appl Microbiol. 1975; 30(4):596-601. PMC: 187237. DOI: 10.1128/am.30.4.596-601.1975. View