» Articles » PMID: 25709537

Advances in Pinhole and Multi-pinhole Collimators for Single Photon Emission Computed Tomography Imaging

Overview
Publisher Thieme
Specialty Nuclear Medicine
Date 2015 Feb 25
PMID 25709537
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The collimator in single photon emission computed tomography (SPECT), is an important part of the imaging chain. One of the most important collimators that used in research, preclinical study, small animal, and organ imaging is the pinhole collimator. Pinhole collimator can improve the tradeoff between sensitivity and resolution in comparison with conventional parallel-hole collimator and facilities diagnosis. However, a major problem with pinhole collimator is a small field of view (FOV). Multi-pinhole collimator has been investigated in order to increase the sensitivity and FOV with a preserved spatial resolution. The geometry of pinhole and multi-pinhole collimators is a critical factor in the image quality and plays a key role in SPECT imaging. The issue of the material and geometry for pinhole and multi-pinhole collimators have been a controversial and much disputed subject within the field of SPECT imaging. On the other hand, recent developments in collimator optimization have heightened the need for appropriate reconstruction algorithms for pinhole SPECT imaging. Therefore, iterative reconstruction algorithms were introduced to minimize the undesirable effect on image quality. Current researches have focused on geometry and configuration of pinhole and multi-pinhole collimation rather than reconstruction algorithm. The lofthole and multi-lofthole collimator are samples of novel designs. The purpose of this paper is to provide a review on recent researches in the pinhole and multi-pinhole collimators for SPECT imaging.

Citing Articles

Integration of advanced 3D SPECT modelling for pinhole collimators into the open-source STIR framework.

Strugari M, Falcon C, Erlandsson K, Hutton B, Brewer K, Thielemans K Front Nucl Med. 2024; 3:1134774.

PMID: 39380953 PMC: 11459977. DOI: 10.3389/fnume.2023.1134774.


Radiation Source Localization Using a Model-Based Approach.

Molnar A, Kiss D, Domozi Z Sensors (Basel). 2023; 23(13).

PMID: 37447831 PMC: 10346540. DOI: 10.3390/s23135983.


Nuclear-medicine probes: Where we are and where we are going.

Gonzalez-Montoro A, Vera-Donoso C, Konstantinou G, Sopena P, Martinez M, Ortiz J Med Phys. 2022; 49(7):4372-4390.

PMID: 35526220 PMC: 9545507. DOI: 10.1002/mp.15690.


Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging.

Hoffmann J, Janssen J, Kanno T, Shibutani T, Onoguchi M, Lapa C EJNMMI Phys. 2020; 7(1):64.

PMID: 33140263 PMC: 7606439. DOI: 10.1186/s40658-020-00335-6.

References
1.
Franc B, Acton P, Mari C, Hasegawa B . Small-animal SPECT and SPECT/CT: important tools for preclinical investigation. J Nucl Med. 2008; 49(10):1651-63. DOI: 10.2967/jnumed.108.055442. View

2.
McQuaid S, Southekal S, Kijewski M, Moore S . Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantification. Phys Med Biol. 2011; 56(21):6983-7000. PMC: 4439202. DOI: 10.1088/0031-9155/56/21/014. View

3.
Steele P, Kirch D, Koss J . Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease. J Nucl Med. 2008; 49(7):1080-9. DOI: 10.2967/jnumed.107.040915. View

4.
Vandenberghe S, DAsseler Y, Van de Walle R, Kauppinen T, Koole M, Bouwens L . Iterative reconstruction algorithms in nuclear medicine. Comput Med Imaging Graph. 2001; 25(2):105-11. DOI: 10.1016/s0895-6111(00)00060-4. View

5.
Zeniya T, Watabe H, Aoi T, Kim K, Teramoto N, Hayashi T . A new reconstruction strategy for image improvement in pinhole SPECT. Eur J Nucl Med Mol Imaging. 2004; 31(8):1166-72. DOI: 10.1007/s00259-004-1510-4. View