» Articles » PMID: 25708031

No Evidence of Superiority in Reducing Outliers of Component Alignment for Patient-specific Instrumentation for Total Knee Arthroplasty: a Systematic Review

Overview
Journal Orthop Surg
Specialty Orthopedics
Date 2015 Feb 25
PMID 25708031
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Patient-specific instrumentation (PSI) technology has been developed to improve alignment when implanting total knee arthroplasty (TKA) and is a new focus in the orthopaedic community. Current controversial data concerning PSI are discussed. A systematic review to compare PSI with conventional instrumentation and assess the radiographic outcomes was performed. Electronic databases (including PubMed, Medline, Embase, the Cochrane Library and the Science Citation Index database) and conference proceedings from 1950 to 2014 in the English language were searched. Data, including relevant patient characteristics, sample size, radiographic method, PSI system manufacturer and outliers of implant positioning and alignment on radiography were independently extracted from all eligible studies by two of the authors. A total of 2739 TKAs were included (1410 performed with PSI and 1329 with conventional instrumentation). There were more TCA outliers (malalignment >3°) and tibial slope outliers (malalignment >3°) in the PSI group than in the conventional group. The other radiographic outcomes assessed, including coronal, sagittal or rotational alignment outliers did not differ between the two groups. With regard to radiographic outcomes, our findings indicate that PSI technology is not superior in reducing outliers of component alignment.

Citing Articles

The Role of 3D-Printed Patient-Specific Instrumentation in Total Knee Arthroplasty: A Literature Review.

Keskinis A, Paraskevopoulos K, Diamantidis D, Ververidis A, Fiska A, Tilkeridis K Cureus. 2023; 15(8):e43321.

PMID: 37700954 PMC: 10493459. DOI: 10.7759/cureus.43321.


Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis.

Tibesku C, Haas S, Saunders C, Harwood D Arch Orthop Trauma Surg. 2022; 143(7):4379-4393.

PMID: 36449066 PMC: 10293358. DOI: 10.1007/s00402-022-04698-6.


Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component.

Sotozawa M, Kumagai K, Yamada S, Nejima S, Inaba Y J Orthop Surg Res. 2022; 17(1):403.

PMID: 36064582 PMC: 9446751. DOI: 10.1186/s13018-022-03298-9.


Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.

Tandogan R, Kort N, Ercin E, van Rooij F, Nover L, Saffarini M Knee Surg Sports Traumatol Arthrosc. 2021; 30(8):2654-2665.

PMID: 33646370 DOI: 10.1007/s00167-021-06495-x.


Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Mehdipour S, Qoreishi M, Keipourfard A Arch Bone Jt Surg. 2020; 8(5):625-632.

PMID: 33088865 PMC: 7547163. DOI: 10.22038/abjs.2020.41571.2124.


References
1.
Plaskos C, Hodgson A, Inkpen K, McGraw R . Bone cutting errors in total knee arthroplasty. J Arthroplasty. 2002; 17(6):698-705. DOI: 10.1054/arth.2002.33564. View

2.
Hafez M, Chelule K, Seedhom B, Sherman K . Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res. 2006; 444:184-92. DOI: 10.1097/01.blo.0000201148.06454.ef. View

3.
Mason J, Fehring T, Estok R, Banel D, Fahrbach K . Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty. 2007; 22(8):1097-106. DOI: 10.1016/j.arth.2007.08.001. View

4.
Bourne R, Chesworth B, Davis A, Mahomed N, Charron K . Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?. Clin Orthop Relat Res. 2009; 468(1):57-63. PMC: 2795819. DOI: 10.1007/s11999-009-1119-9. View

5.
Parratte S, Pagnano M, Trousdale R, Berry D . Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010; 92(12):2143-9. DOI: 10.2106/JBJS.I.01398. View