Contribution of Exhaled Nitric Oxide Measurement in Airway Inflammation Assessment in Asthma. A Position Paper from the French Speaking Respiratory Society

Overview
Journal Rev Mal Respir
Specialty Pulmonary Medicine
Date 2015 Feb 24
PMID 25704902
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Nitric oxide (NO) is both a gas and a ubiquitous inter- and intracellular messenger with numerous physiological functions. As its synthesis is markedly increased during inflammatory processes, NO can be used as a surrogate marker of acute and/or chronic inflammation. It is possible to quantify fractional concentration of NO in exhaled breath (FENO) to detect airway inflammation, and thus improve the diagnosis of asthma by better characterizing asthmatic patients with eosinophilic bronchial inflammation, and eventually improve the management of targeted asthmatic patients. FENO measurement can therefore be viewed as a new, reproducible and easy to perform pulmonary function test. Measuring FENO is the only non-invasive pulmonary function test allowing (1) detecting, (2) quantifying and (3) monitoring changes in inflammatory processes during the course of various respiratory disorders, including corticosensitive asthma.

Citing Articles

Guiding therapy by fractional exhaled nitric oxide & impulse oscillometry parameters in non-asthmatic individuals with chronic cough.

Duan H, Xiong Y, Xiong S, Zhou Q Indian J Med Res. 2025; 161(1):65-71.

PMID: 40036107 PMC: 11878660. DOI: 10.25259/IJMR_307_2024.


Distal Lung Inflammation Assessed by Alveolar Concentration of Nitric Oxide Is an Individualised Biomarker of Severe COVID-19 Pneumonia.

Hua-Huy T, Gunther S, Lorut C, Subileau M, Aubourg F, Morbieu C J Pers Med. 2022; 12(10).

PMID: 36294770 PMC: 9605039. DOI: 10.3390/jpm12101631.


An Evidence-Based Review of Application Devices for Nitric Oxide Concentration Determination from Exhaled Air in the Diagnosis of Inflammation and Treatment Monitoring.

Wyszynska M, Nitsze-Wierzba M, Czelakowska A, Kasperski J, Zywiec J, Skucha-Nowak M Molecules. 2022; 27(13).

PMID: 35807523 PMC: 9268246. DOI: 10.3390/molecules27134279.


Exhaled Nitric Oxide Level in Pharynx Angioedema.

Moos L, Zajac M, Brzoza Z J Clin Med. 2022; 11(3).

PMID: 35160089 PMC: 8836686. DOI: 10.3390/jcm11030637.


The association between serum apolipoprotein B and fractional exhaled nitric oxide in bronchial asthma patients.

Heo J, Lee H, Han S, Kang H, Kwon S, Lee S J Thorac Dis. 2021; 13(7):4195-4206.

PMID: 34422348 PMC: 8339740. DOI: 10.21037/jtd-20-3314.