Reliability Assessment for Pulse Wave Measurement Using Artificial Pulse Generator

Overview
Publisher Informa Healthcare
Date 2015 Feb 20
PMID 25693606
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

This study aimed to assess intrinsic reliabilities of devices for pulse wave measurement (PWM). An artificial pulse generator system was constructed to create a periodic pulse wave. The stability of the periodic output was tested by the DP103 pressure transducer. The pulse generator system was then used to evaluate the TD01C system. Test-re-test and inter-device reliability assessments were conducted on the TD01C system. First, 11 harmonic components of the pulse wave were calculated using Fourier series analysis. For each harmonic component, coefficient of variation (CV), intra-class correlation coefficient (ICC) and Bland-Altman plot were used to determine the degree of reliability of the TD01C system. In addition, device exclusion criteria were pre-specified to improve consistency of devices. The artificial pulse generator system was stable to evaluate intrinsic reliabilities of devices for PWM (ICCs > 0.95, p < 0.001). TD01C was reliable for repeated measurements (ICCs of test-re-test reliability > 0.95, p < 0.001; CVs all < 3%). Device exclusion criteria successfully excluded the device with defect; therefore, the criteria reduced inter-device CVs of harmonics and improved consistency of the selected devices for all harmonic components. This study confirmed the feasibility of intrinsic reliability assessment of devices for PWM using an artificial pulse generator system. Moreover, potential novel findings on the assessment combined with device exclusion criteria could be a useful method to select the measuring devices and to evaluate the qualities of them in PWM.

Citing Articles

Peripheral pulse harmonic analysis and its clinical application: A systematic review.

Hsiao K, Kang J, Wu Y, Chang H, Yang C J Tradit Complement Med. 2024; 14(2):223-236.

PMID: 38481553 PMC: 10927382. DOI: 10.1016/j.jtcme.2023.11.006.


A First Step towards a Comprehensive Approach to Harmonic Analysis of Synchronous Peripheral Volume Pulses: A Proof-of-Concept Study.

Wu H, Haryadi B, Chen J J Pers Med. 2021; 11(12).

PMID: 34945735 PMC: 8707287. DOI: 10.3390/jpm11121263.


Non-Invasive radial pressure wave analysis may digitally predict women's risks of type 2 diabetes (T2DM): A case and control group study.

Chen C, Liao K, Wang S, Chen S, Chang C, Wang T PLoS One. 2021; 16(10):e0259269.

PMID: 34714885 PMC: 8555842. DOI: 10.1371/journal.pone.0259269.


Chinese herbs and acupuncture to improve cognitive function in Alzheimer's disease.

Wuli W, Harn H, Chiou T, Lin S Tzu Chi Med J. 2021; 33(2):122-127.

PMID: 33912408 PMC: 8059467. DOI: 10.4103/tcmj.tcmj_51_20.


Risk assessment of macrovascular and microvascular events in patients with type 2 diabetes by analyzing the amplitude variation of the fourth harmonic component of radial pulse wave.

Liao K, Chang C, Wang S, Chang Y, Chen Y, Wang G Physiol Rep. 2019; 7(19):e14252.

PMID: 31591828 PMC: 6779930. DOI: 10.14814/phy2.14252.