Development of a Noncontact Heart Rate Monitoring System for Sedentary Behavior Based on an Accelerometer Attached to a Chair

Overview
Journal Physiol Meas
Date 2015 Feb 17
PMID 25684320
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor heart rate (HR) in a noncontact and unconstrained way while subjects were seated, by attaching an accelerometer on the backrest of a chair. Acceleration signals were obtained three times from 20 healthy adults, a detection algorithm was applied, and HR detection performance was evaluated by comparing the R-peak values from the ECG. The system had excellent performance results, with a sensitivity of 96.10% and a positive predictive value of 96.43%. In addition, the HR calculated by the new system developed in this study was compared with HR calculated using ECG. The new system exhibited excellent performance; its results were strongly correlated with that of ECG (r = 0.97, p [Formula: see text] 0.0001; average difference of -0.08  ±  4.60 [mean ± 1.96∙standard deviation] in Bland-Altman analysis). Accordingly, the method presented in this study is expected to be applicable for evaluating diverse autonomic nervous system components in a noncontact and unconstrained way using an accelerometer to monitor the HR of sedentary workers or adolescents.

Citing Articles

Prenatal Monitoring of Perinatal Pregnant Women and Fetus Based on a Smart Electronic Fetal Monitoring System.

Sun Y, Jiang S J Healthc Eng. 2022; 2022:5073636.

PMID: 36437815 PMC: 9699735. DOI: 10.1155/2022/5073636.


Viaxl: A Solution of a Low-Cost Real-Time Visual Accelerometer Based on Laser Speckle Optical Flow Detection.

Li Z, Yang W, Xiong X, Wang Z, Zou X Sensors (Basel). 2020; 20(24).

PMID: 33302588 PMC: 7764063. DOI: 10.3390/s20247033.


Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array.

Jiang Y, Deng S, Sun H, Qi Y Sensors (Basel). 2019; 19(2).

PMID: 30658466 PMC: 6358939. DOI: 10.3390/s19020368.


Infrared Camera-Based Non-contact Measurement of Brain Activity From Pupillary Rhythms.

Park S, Whang M Front Physiol. 2018; 9:1400.

PMID: 30364205 PMC: 6192458. DOI: 10.3389/fphys.2018.01400.


Cardiopulmonary Coupling Analysis Using Home Sleep Monitoring System Based on Air Mattress.

Park J, Urtnasan E, Joo E, Lee K J Med Syst. 2017; 41(11):177.

PMID: 28952010 DOI: 10.1007/s10916-017-0824-2.