Evaluation of In-situ Calibration of Chemcatcher Passive Samplers for 322 Micropollutants in Agricultural and Urban Affected Rivers

Overview
Journal Water Res
Date 2015 Feb 4
PMID 25647166
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

In a large field study, the in-situ calibration of the Chemcatcher(®) passive sampler - styrenedivinylbenzene (SDB) covered by a polyether sulfone (PES) membrane - was evaluated for 322 polar organic micropollutants. Five rivers with different agricultural and urban influences were monitored from March to July 2012 with two methods i) two-week time-proportional composite water samples and ii) two-week passive sampler deployment. All substances - from different substance classes with logKow -3 to 5, and neutral, anionic, cationic, and zwitterionic species - were analyzed by liquid-chromatography high-resolution tandem mass spectrometry. This study showed that SDB passive samplers are well-suited for the qualitative screening of polar micropollutants because the number of detected substances was similar (204 for SDB samples vs. 207 for composite water samples), limits of quantification were comparable (median: 1.3 ng/L vs. 1.6 ng/L), and the handling in the field and laboratory is fast and easy. The determination of in-situ calibrated sampling rates (field Rs) was possible for 88 compounds where the R(2) from the regression (water concentration vs. sampled mass on SDB disk) was >0.75. Substances with moderately fluctuating river concentrations such as pharmaceuticals showed much better correlations than substances with highly fluctuating concentrations such as pesticides (R(2) > 0.75 for 93% and 60% of the investigated substances, respectively). Flow velocity (0.05-0.8 m/s) and temperature (5-20 °C) did not have an evident effect on the field Rs. It was observed that ionic species had significantly lower field Rs than neutral species. Due to the complexity of the different transport processes, a correlation between determined field Rs and logDow could only predict Rs with large uncertainties. We conclude that only substances with relatively constant river concentrations can be quantified accurately in the field by passive sampling if substance-specific Rs are determined. For that purpose, the proposed in-situ calibration is a very robust method and the substance specific Rs can be used in future monitoring studies in rivers with similar environmental conditions (i.e., flow velocity, temperature, pH).

Citing Articles

Surface water monitoring of chemicals associated with animal husbandry in an agricultural region in the Netherlands using passive sampling.

Rakonjac N, Roex E, Beeltje H Environ Monit Assess. 2024; 196(7):670.

PMID: 38940882 PMC: 11213807. DOI: 10.1007/s10661-024-12818-5.


Survey of Appearance and temporal concentrations of polar organic pollutants in Saxon waters.

Romerscheid M, Paschke A, Schuurmann G Heliyon. 2024; 10(1):e23378.

PMID: 38192827 PMC: 10772579. DOI: 10.1016/j.heliyon.2023.e23378.


Antimicrobial Transformation Products in the Aquatic Environment: Global Occurrence, Ecotoxicological Risks, and Potential of Antibiotic Resistance.

Loffler P, Escher B, Baduel C, Virta M, Lai F Environ Sci Technol. 2023; 57(26):9474-9494.

PMID: 37335844 PMC: 10324322. DOI: 10.1021/acs.est.2c09854.


Combining Passive Sampling with Suspect and Nontarget Screening to Characterize Organic Micropollutants in Streams Draining Mixed-Use Watersheds.

Wang S, Basijokaite R, Murphy B, Kelleher C, Zeng T Environ Sci Technol. 2022; 56(23):16726-16736.

PMID: 36331382 PMC: 9730844. DOI: 10.1021/acs.est.2c02938.


Evaluation of Chemcatcher® passive samplers for pesticide monitoring using high-frequency catchment scale data.

Farrow L, Morton P, Cassidy R, Floyd S, McRoberts W, Doody D J Environ Manage. 2022; 324:116292.

PMID: 36183532 PMC: 9666346. DOI: 10.1016/j.jenvman.2022.116292.