Distribution of Posterior Corneal Astigmatism According to Axis Orientation of Anterior Corneal Astigmatism

Overview
Journal PLoS One
Date 2015 Jan 28
PMID 25625283
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the distribution of posterior corneal astigmatism in eyes with with-the-rule (WTR) and against-the-rule (ATR) anterior corneal astigmatism.

Methods: We retrospectively examined six hundred eight eyes of 608 healthy subjects (275 men and 333 women; mean age ± standard deviation, 55.3 ± 20.2 years). The magnitude and axis orientation of anterior and posterior corneal astigmatism were determined with a rotating Scheimpflug system (Pentacam HR, Oculus) when we divided the subjects into WTR and ATR anterior corneal astigmatism groups.

Results: The mean magnitudes of anterior and posterior corneal astigmatism were 1.14 ± 0.76 diopters (D), and 0.37 ± 0.19 D, respectively. We found a significant correlation between the magnitudes of anterior and posterior corneal astigmatism (Pearson correlation coefficient r = 0.4739, P<0.001). In the WTR anterior astigmatism group, we found ATR astigmatism of the posterior corneal surface in 402 eyes (96.6%). In the ATR anterior astigmatism group, we found ATR posterior corneal astigmatism in 82 eyes (73.9%). Especially in eyes with ATR anterior corneal astigmatism of 1 D or more and 1.5 D or more, ATR posterior corneal astigmatism was found in 28 eyes (59.6%) and 9 eyes (42.9%), respectively.

Conclusions: WTR anterior astigmatism and ATR posterior astigmatism were found in approximately 68% and 91% of eyes, respectively. The magnitude and the axis orientation of posterior corneal astigmatism were not constant, especially in eyes having high ATR anterior corneal astigmatism, as is often the case in patients who have undergone toric IOL implantation.

Citing Articles

Correlations of anterior and posterior corneal parameters in Chinese myopic patients: a retrospective multicenter study.

Hu Y, Wang Y, Du Z, Zhu S, Xiong L, Fang X Quant Imaging Med Surg. 2025; 15(1):88-102.

PMID: 39839038 PMC: 11744138. DOI: 10.21037/qims-24-333.


Prevalence of interocular symmetry in corneal astigmatism and the possible influence of age, sex and refractive error.

Salvador-Roger R, Mico V, Esteve-Taboada J Ophthalmic Physiol Opt. 2024; 45(2):352-360.

PMID: 39679636 PMC: 11823323. DOI: 10.1111/opo.13433.


Descemet membrane endothelial keratoplasty combined with presbyopia-correcting and toric intraocular lenses - a narrative review.

Rodriguez-Calvo-de-Mora M, Rocha-de-Lossada C, Romano V, Rodriguez-Vallejo M, Fernandez J BMC Ophthalmol. 2023; 23(1):483.

PMID: 38007433 PMC: 10675930. DOI: 10.1186/s12886-023-03240-5.


Corneal refractive error and astigmatism in patients aged 6 to 18 years with a history of retinopathy of prematurity and birth weight of <1500 g.

Tachikawa T, Ueno R, Mita T, Yuzurihara D, Noda T Jpn J Ophthalmol. 2023; 68(1):42-49.

PMID: 38001368 DOI: 10.1007/s10384-023-01026-2.


Revisiting Javal's rule: a fresh and improved power vector approach according to age.

Salvador-Roger R, Albarran-Diego C, Garzon N, Garcia-Montero M, Munoz G, Mico V Graefes Arch Clin Exp Ophthalmol. 2023; 262(1):249-260.

PMID: 37552315 PMC: 10805827. DOI: 10.1007/s00417-023-06195-x.


References
1.
Shankar H, Taranath D, Santhirathelagan C, Pesudovs K . Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008; 34(1):103-13. DOI: 10.1016/j.jcrs.2007.09.013. View

2.
Dubbelman M, Sicam V, van der Heijde G . The shape of the anterior and posterior surface of the aging human cornea. Vision Res. 2005; 46(6-7):993-1001. DOI: 10.1016/j.visres.2005.09.021. View

3.
Pinero D, Saenz Gonzalez C, Alio J . Intraobserver and interobserver repeatability of curvature and aberrometric measurements of the posterior corneal surface in normal eyes using Scheimpflug photography. J Cataract Refract Surg. 2008; 35(1):113-20. DOI: 10.1016/j.jcrs.2008.10.010. View

4.
Kawamorita T, Uozato H, Kamiya K, Bax L, Tsutsui K, Aizawa D . Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement. J Cataract Refract Surg. 2008; 35(1):127-33. DOI: 10.1016/j.jcrs.2008.10.019. View

5.
Ho J, Tsai C, Liou S . Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement. Am J Ophthalmol. 2009; 147(5):788-95, 795.e1-2. DOI: 10.1016/j.ajo.2008.12.020. View