» Articles » PMID: 25618045

Equivalence of Time and Aperture Domain Additive Noise in Ultrasound Coherence

Overview
Journal J Acoust Soc Am
Date 2015 Jan 26
PMID 25618045
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Ultrasonic echoes backscattered from diffuse media, recorded by an array transducer and appropriately focused, demonstrate coherence predicted by the van Cittert-Zernike theorem. Additive noise signals from off-axis scattering, reverberation, phase aberration, and electronic (thermal) noise can all superimpose incoherent or partially coherent signals onto the recorded echoes, altering the measured coherence. An expression is derived to describe the effect of uncorrelated random channel noise in terms of the noise-to-signal ratio. Equivalent descriptions are made in the aperture dimension to describe uncorrelated magnitude and phase apodizations of the array. Binary apodization is specifically described as an example of magnitude apodization and adjustments are presented to minimize the artifacts caused by finite signal length. The effects of additive noise are explored in short-lag spatial coherence imaging, an image formation technique that integrates the calculated coherence curve of acquired signals up to a small fraction of the array length for each lateral and axial location. A derivation of the expected contrast as a function of noise-to-signal ratio is provided and validation is performed in simulation.

Citing Articles

Far-focus compound ultrasound imaging with lag-one coherence-based zero-cross factor.

Zheng C, Tang Y, Wang Y, Wang Y, Peng H Technol Health Care. 2024; 32(6):3967-3984.

PMID: 39031397 PMC: 11612989. DOI: 10.3233/THC-231452.


An Automated Region-Selection Method for Adaptive ALARA Ultrasound Imaging.

Flint K, Barre E, Huber M, McNally P, Ellestad S, Trahey G IEEE Trans Ultrason Ferroelectr Freq Control. 2022; 69(7):2257-2269.

PMID: 35507609 PMC: 9578508. DOI: 10.1109/TUFFC.2022.3172690.


Spatial Coherence in Medical Ultrasound: A Review.

Long J, Trahey G, Bottenus N Ultrasound Med Biol. 2022; 48(6):975-996.

PMID: 35282988 PMC: 9067166. DOI: 10.1016/j.ultrasmedbio.2022.01.009.


Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.

Vienneau E, Ozgun K, Byram B IEEE Trans Ultrason Ferroelectr Freq Control. 2022; 69(4):1337-1352.

PMID: 35175919 PMC: 9083333. DOI: 10.1109/TUFFC.2022.3152717.


Reverberation Clutter Suppression Using 2-D Spatial Coherence Analysis.

Ahmed R, Bottenus N, Long J, Trahey G IEEE Trans Ultrason Ferroelectr Freq Control. 2021; 69(1):84-97.

PMID: 34437060 PMC: 8845080. DOI: 10.1109/TUFFC.2021.3108059.


References
1.
Lacefield J, Waag R . Spatial coherence analysis applied to aberration correction using a two-dimensional array system. J Acoust Soc Am. 2003; 112(6):2558-66. DOI: 10.1121/1.1511756. View

2.
Fink M, Mallart R, Cancre F . The random phase transducer: a new technique for incoherent processing-basic principles and theory. IEEE Trans Ultrason Ferroelectr Freq Control. 1990; 37(2):54-69. DOI: 10.1109/58.46970. View

3.
Li P, Li M . Adaptive imaging using the generalized coherence factor. IEEE Trans Ultrason Ferroelectr Freq Control. 2003; 50(2):128-41. DOI: 10.1109/tuffc.2003.1182117. View

4.
Walker W, Trahey G . Speckle coherence and implications for adaptive imaging. J Acoust Soc Am. 1997; 101(4):1847-58. DOI: 10.1121/1.418235. View

5.
Brands P, Hoeks A, Reneman R . The effect of echo suppression on the mean velocity estimation range of the RF cross-correlation model estimator. Ultrasound Med Biol. 1995; 21(7):945-59. DOI: 10.1016/0301-5629(95)00028-p. View