» Articles » PMID: 25613304

Deep-tissue Oxygen Monitoring in the Brain of Rabbits for Stroke Research

Overview
Journal Stroke
Date 2015 Jan 24
PMID 25613304
Citations 10
Authors
Affiliations
Soon will be listed here.
Citing Articles

The effects of carbogen and hyperbaric oxygen treatment on fracture healing in rats.

Menendi U, Nusran G, Kaymaz B, Tiskaoglu R, Yilmaz O, Canbey Goret C Ulus Travma Acil Cerrahi Derg. 2022; 28(4):411-417.

PMID: 35485502 PMC: 10443132. DOI: 10.14744/tjtes.2021.02575.


A Review of Low-Frequency EPR Technology for the Measurement of Brain pO2 and Oxidative Stress.

Weaver J, Liu K Appl Magn Reson. 2022; 52(10):1379-1394.

PMID: 35340811 PMC: 8945541. DOI: 10.1007/s00723-021-01384-5.


Evaluation of a Refined Implantable Resonator for Deep-Tissue EPR Oximetry in the Clinic.

Chen E, Tse D, Hou H, Schreiber W, Schaner P, Kmiec M Appl Magn Reson. 2021; 52(10):1321-1342.

PMID: 34744319 PMC: 8570533. DOI: 10.1007/s00723-021-01376-5.


Tumor Hypoxia Regulates Immune Escape/Invasion: Influence on Angiogenesis and Potential Impact of Hypoxic Biomarkers on Cancer Therapies.

Abou Khouzam R, Brodaczewska K, Filipiak A, Zeinelabdin N, Buart S, Szczylik C Front Immunol. 2021; 11:613114.

PMID: 33552076 PMC: 7854546. DOI: 10.3389/fimmu.2020.613114.


Modular imaging system: Rapid scan EPR at 800 MHz.

Tseytlin O, Guggilapu P, Bobko A, AlAhmad H, Xu X, Epel B J Magn Reson. 2019; 305:94-103.

PMID: 31238278 PMC: 6656609. DOI: 10.1016/j.jmr.2019.06.003.


References
1.
Hou H, Dong R, Li H, Williams B, Lariviere J, Hekmatyar S . Dynamic changes in oxygenation of intracranial tumor and contralateral brain during tumor growth and carbogen breathing: a multisite EPR oximetry with implantable resonators. J Magn Reson. 2011; 214(1):22-8. PMC: 3730127. DOI: 10.1016/j.jmr.2011.09.043. View

2.
OHara J, Hou H, Demidenko E, Springett R, Khan N, Swartz H . Simultaneous measurement of rat brain cortex PtO2 using EPR oximetry and a fluorescence fiber-optic sensor during normoxia and hyperoxia. Physiol Meas. 2005; 26(3):203-13. DOI: 10.1088/0967-3334/26/3/006. View

3.
Smirnov A, Norby S, Clarkson R, Walczak T, Swartz H . Simultaneous multi-site EPR spectroscopy in vivo. Magn Reson Med. 1993; 30(2):213-20. DOI: 10.1002/mrm.1910300210. View

4.
Wardlaw J, Murray V, Berge E, Del Zoppo G, Sandercock P, Lindley R . Recombinant tissue plasminogen activator for acute ischaemic stroke: an updated systematic review and meta-analysis. Lancet. 2012; 379(9834):2364-72. PMC: 3386494. DOI: 10.1016/S0140-6736(12)60738-7. View

5.
Ahmad R, Kuppusamy P . Theory, instrumentation, and applications of electron paramagnetic resonance oximetry. Chem Rev. 2010; 110(5):3212-36. PMC: 2868962. DOI: 10.1021/cr900396q. View