Automated Synthesis and PET Evaluation of Both Enantiomers of [¹⁸F]FMISO

Overview
Journal Nucl Med Biol
Publisher Elsevier
Date 2015 Jan 18
PMID 25595134
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: [(18)F]FMISO, the widely used positron emission tomography (PET) hypoxia tracer, is a chiral compound clinically used as a racemic mixture. The purpose of this study was to synthesize the individual (R)- and the (S)- enantiomers of [(18)F]FMISO and compare their PET imaging characteristics.

Methods: The radiosynthesis of enantiopure (R)- and (S)-[(18)F]FMISO was based on Co(salen) (N,N'-bis(3,5-di-tert-butylsalicylidene)-1,2-cyclohexanediaminocobalt)-mediated opening of enantiopure epoxides with [(18)F]HF. The uptake and clearance of the individual [(18)F]FMISO antipodes were investigated using micro-PET/CT imaging performed on mice bearing FaDu tumors. Image-derived biodistribution was obtained from micro-PET/CT scans performed at 1 and 3 hours post injection (p.i.). In addition, the uptake patterns of each enantiomer were observed using two-hour dynamic micro-PET/CT scans, and the time-activity curves from different organs were compared.

Results: The individual (R)- and (S)-[(18)F]FMISO enantiomers were synthesized in one step with high enantiomeric excess (ee)>99% and radiochemical purity>97% using custom-made automation module. The dynamic micro-PET/CT scanning revealed a faster initial uptake of the (R)-[(18)F]FMISO enantiomer in tumor and muscle tissues, however the difference became progressively smaller with time. The tumor-to-muscle (T/M) and tumor-to-liver (T/L) ratios remained nearly identical for the (R)- and (S)-forms at all time points. The micro-PET/CT imaging at 1 and 3 hours p.i. did not show any significant enantioselective tissue uptake.

Conclusions: Although the (R)-enantiomer of [(18)F]FMISO demonstrated a somewhat faster initial tumor and muscle uptake no significant enantioselective tissue uptake was observed at later time points. The T/M- and T/L- ratios for the (R)- and (S)-forms were the same within the experimental error at all times. Therefore, the use of enantiopure [(18)F]FMISO is unlikely to present any practical clinical benefit for PET imaging.

Citing Articles

Development and application of a fully automatic multi-function cassette module Mortenon M1 for radiopharmaceutical synthesis.

Cui F, Lv X, Yan C, Eng W, Yu S, Zheng Q Ann Nucl Med. 2023; 38(4):247-263.

PMID: 38145430 DOI: 10.1007/s12149-023-01893-2.


Synthesis of [F]FMISO, a hypoxia-specific imaging probe for PET, an overview from a radiochemist's perspective.

Kniess T, Zessin J, Mading P, Kuchar M, Kiss O, Kopka K EJNMMI Radiopharm Chem. 2023; 8(1):5.

PMID: 36897480 PMC: 10006378. DOI: 10.1186/s41181-023-00190-7.