» Articles » PMID: 25565133

Generating Patient Specific Pseudo-CT of the Head from MR Using Atlas-based Regression

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2015 Jan 8
PMID 25565133
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

Radiotherapy planning and attenuation correction of PET images require simulation of radiation transport. The necessary physical properties are typically derived from computed tomography (CT) images, but in some cases, including stereotactic neurosurgery and combined PET/MR imaging, only magnetic resonance (MR) images are available. With these applications in mind, we describe how a realistic, patient-specific, pseudo-CT of the head can be derived from anatomical MR images. We refer to the method as atlas-based regression, because of its similarity to atlas-based segmentation. Given a target MR and an atlas database comprising MR and CT pairs, atlas-based regression works by registering each atlas MR to the target MR, applying the resulting displacement fields to the corresponding atlas CTs and, finally, fusing the deformed atlas CTs into a single pseudo-CT. We use a deformable registration algorithm known as the Morphon and augment it with a certainty mask that allows a tailoring of the influence certain regions are allowed to have on the registration. Moreover, we propose a novel method of fusion, wherein the collection of deformed CTs is iteratively registered to their joint mean and find that the resulting mean CT becomes more similar to the target CT. However, the voxelwise median provided even better results; at least as good as earlier work that required special MR imaging techniques. This makes atlas-based regression a good candidate for clinical use.

Citing Articles

Clinical validation of MR-generated synthetic CT by MRCAT for brain tumor radiotherapy.

Yip T, Li Z, Li T J Appl Clin Med Phys. 2024; 26(1):e14494.

PMID: 39673148 PMC: 11713499. DOI: 10.1002/acm2.14494.


Advancements in synthetic CT generation from MRI: A review of techniques, and trends in radiation therapy planning.

Bahloul M, Jabeen S, Benoumhani S, Alsaleh H, Belkhatir Z, Al-Wabil A J Appl Clin Med Phys. 2024; 25(11):e14499.

PMID: 39325781 PMC: 11539972. DOI: 10.1002/acm2.14499.


Clinical feasibility of deep learning-based synthetic CT images from T2-weighted MR images for cervical cancer patients compared to MRCAT.

Kim H, Yoo S, Kim J, Kim Y, Lee J, Kim C Sci Rep. 2024; 14(1):8504.

PMID: 38605094 PMC: 11009270. DOI: 10.1038/s41598-024-59014-6.


A systematic literature review: deep learning techniques for synthetic medical image generation and their applications in radiotherapy.

Sherwani M, Gopalakrishnan S Front Radiol. 2024; 4:1385742.

PMID: 38601888 PMC: 11004271. DOI: 10.3389/fradi.2024.1385742.


Adoption of Hybrid MRI-Linac Systems for the Treatment of Brain Tumors: A Systematic Review of the Current Literature Regarding Clinical and Technical Features.

Guerini A, Nici S, Magrini S, Riga S, Toraci C, Pegurri L Technol Cancer Res Treat. 2023; 22:15330338231199286.

PMID: 37774771 PMC: 10542234. DOI: 10.1177/15330338231199286.