» Articles » PMID: 25527248

Clinical Evaluation Comparing the Fit of All-ceramic Crowns Obtained from Silicone and Digital Intraoral Impressions Based on Wavefront Sampling Technology

Overview
Journal J Dent
Publisher Elsevier
Specialty Dentistry
Date 2014 Dec 21
PMID 25527248
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The aim of this study was to compare the fit of ceramic crowns fabricated from conventional silicone impressions with the fit of ceramic crowns fabricated from intraoral digital impressions.

Methods: Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impression (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interface and then cut in 2mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnification of 40×. Data was analysed by using Wilcoxon signed rank test (α=0.05).

Results: Internal adaptation values were significantly affected by the impression technique (p=0.001). Mean marginal gap was 76.33 ± 65.32 μm for the crowns of the IDI group and 91.46 ± 72.17 μm for the CI group.

Conclusion: All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions.

Clinical Significance: Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers.

Citing Articles

Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study.

Jain S, Sayed M, Khawaji R, Hakami G, Solan E, Daish M Med Sci Monit. 2024; 30:e946624.

PMID: 39645575 PMC: 11636004. DOI: 10.12659/MSM.946624.


Comparative Evaluation of Digital and Conventional Workflows for the Fabrication of Multi-Unit Implant-Supported Fixed Restorations: An Empty Review.

Hashemi A, Hasanzadeh M, Khraisat A, Alikhasi M Front Dent. 2024; 21:20.

PMID: 39011351 PMC: 11247140. DOI: 10.18502/fid.v21i20.15714.


Comparative evaluation of the marginal fit of computer-aided design-computer aided manufacturing fabricated crowns from direct and indirect digital impression - A systematic review.

Seshan R, Karthikeyan H, Rajan R, Rajakumaran A, Varadan P, Gopal R J Conserv Dent Endod. 2024; 27(2):140-145.

PMID: 38463477 PMC: 10923227. DOI: 10.4103/JCDE.JCDE_42_23.


Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions.

Vargas-Corral F, Vargas-Corral A, Rodriguez-Valverde M, Bravo M, Rosales-Leal J J Adv Prosthodont. 2024; 16(1):57-65.

PMID: 38455677 PMC: 10917630. DOI: 10.4047/jap.2024.16.1.57.


Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems.

Bae E, Cho W, Park D, Hwang S, Lee S, Yun M J Adv Prosthodont. 2023; 15(3):155-170.

PMID: 37441720 PMC: 10333096. DOI: 10.4047/jap.2023.15.3.155.