» Articles » PMID: 25503684

Particle Size Distribution and Air Pollution Patterns in Three Urban Environments in Xi'an, China

Overview
Date 2014 Dec 16
PMID 25503684
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Three urban environments, office, apartment and restaurant, were selected to investigate the indoor and outdoor air quality as an inter-comparison in which CO2, particulate matter (PM) concentration and particle size ranging were concerned. In this investigation, CO2 level in the apartment (623 ppm) was the highest among the indoor environments and indoor levels were always higher than outdoor levels. The PM10 (333 µg/m(3)), PM2.5 (213 µg/m(3)), PM1 (148 µg/m(3)) concentrations in the office were 10-50% higher than in the restaurant and apartment, and the three indoor PM10 levels all exceeded the China standard of 150 µg/m(3). Particles ranging from 0.3 to 0.4 µm, 0.4 to 0.5 µm and 0.5 to 0.65 µm make largest contribution to particle mass in indoor air, and fine particles number concentrations were much higher than outdoor levels. Outdoor air pollution is mainly affected by heavy traffic, while indoor air pollution has various sources. Particularly, office environment was mainly affected by outdoor sources like soil dust and traffic emission; apartment particles were mainly caused by human activities; restaurant indoor air quality was affected by multiple sources among which cooking-generated fine particles and the human steam are main factors.

Citing Articles

Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown.

Kaliszewski M, Wlodarski M, Mlynczak J, Kopczynski K Sensors (Basel). 2020; 20(24).

PMID: 33353048 PMC: 7766947. DOI: 10.3390/s20247290.


Aging with higher fractional exhaled nitric oxide levels are associated with increased urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine concentrations in elder females.

Hou J, Yang Y, Huang X, Song Y, Sun H, Wang J Environ Sci Pollut Res Int. 2016; 23(23):23815-23824.

PMID: 27628697 DOI: 10.1007/s11356-016-7491-6.

References
1.
Lee S, Li W, Chan L . Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong. Sci Total Environ. 2001; 279(1-3):181-93. DOI: 10.1016/s0048-9697(01)00765-3. View

2.
Cao J, Lee S, Chow J, Cheng Y, Ho K, Fung K . Indoor/outdoor relationships for PM2.5 and associated carbonaceous pollutants at residential homes in Hong Kong - case study. Indoor Air. 2005; 15(3):197-204. DOI: 10.1111/j.1600-0668.2005.00336.x. View

3.
Parker J, Larson R, Eskelson E, Wood E, Veranth J . Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes. Indoor Air. 2008; 18(5):386-93. DOI: 10.1111/j.1600-0668.2008.00539.x. View

4.
Jung K, Bernabe K, Moors K, Yan B, Chillrud S, Whyatt R . Effects of Floor Level and Building Type on Residential Levels of Outdoor and Indoor Polycyclic Aromatic Hydrocarbons, Black Carbon, and Particulate Matter in New York City. Atmosphere (Basel). 2011; 2(2):96-109. PMC: 3163303. DOI: 10.3390/atmos2020096. View

5.
Jiang R, Bell M . A comparison of particulate matter from biomass-burning rural and non-biomass-burning urban households in northeastern China. Environ Health Perspect. 2008; 116(7):907-14. PMC: 2453159. DOI: 10.1289/ehp.10622. View