» Articles » PMID: 25496118

Fabrication of Novel Nitrogen-doped Graphene-hollow AuPd Nanoparticle Hybrid Films for the Highly Efficient Electrocatalytic Reduction of H2O2

Overview
Date 2014 Dec 16
PMID 25496118
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Hollow AuPd (hAuPd) alloy nanoparticles (NPs) were prepared through simultaneous reduction of HAuCl4 and Na2PdCl4 using Co NPs as sacrificial template (i.e., reductant). Then, the hAuPd NPs were assembled on nitrogen-doped graphene (NG) to prepare an NG-hAuPd hybrid film. The obtained NG-hAuPd composite showed higher electrocatalytic activity toward the reduction of H2O2, compared with graphene-hAuPd hybrid, NG-solid AuPd hybrid, and hAuPd NPs. The enhanced performance was related to the hollow structure of hAuPd NPs and the synergistic effect between NG and hAuPd NPs. Under optimum conditions, the NG-hAuPd hybrid film showed a linear response to H2O2 in the range of 0.1-20 μM, with a sensitivity of 5095.5 μA mM(-1) cm(-2)and a comparable detection limit of 0.02 μM (S/N = 3). These results demonstrated that the NG-hAuPd composite was a promising electrocatalytic material for constructing sensors, etc.

Citing Articles

Enlightening the bimetallic effect of Au@Pd nanoparticles on Ni oxide nanostructures with enhanced catalytic activity.

Bruno L, Scuderi M, Priolo F, Falciola L, Mirabella S Sci Rep. 2023; 13(1):3203.

PMID: 36828859 PMC: 9957992. DOI: 10.1038/s41598-023-29679-6.


A Core-Shell Au@TiO and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of HO in Human Blood Serum and Saliva.

Saeed A, Abbas M, El-Hawary W, Issa Y, Singh B Biosensors (Basel). 2022; 12(10).

PMID: 36290916 PMC: 9599508. DOI: 10.3390/bios12100778.


Optimization of gold-palladium core-shell nanowires towards HO reduction by adjusting shell thickness.

Dong Y, Chen Q, Cheng X, Li H, Chen J, Zhang X Nanoscale Adv. 2022; 2(2):785-791.

PMID: 36133255 PMC: 9417247. DOI: 10.1039/c9na00726a.


A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Krishnan S, Singh E, Singh P, Meyyappan M, Nalwa H RSC Adv. 2022; 9(16):8778-8881.

PMID: 35517682 PMC: 9062009. DOI: 10.1039/c8ra09577a.


Detection Technologies for Reactive Oxygen Species: Fluorescence and Electrochemical Methods and Their Applications.

Duanghathaipornsuk S, Farrell E, Alba-Rubio A, Zelenay P, Kim D Biosensors (Basel). 2021; 11(2).

PMID: 33498809 PMC: 7911324. DOI: 10.3390/bios11020030.