High-strength, Surface-porous Polyether-ether-ketone for Load-bearing Orthopedic Implants

Abstract

Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% and interconnectivity of 99.9±0.1%. Monotonic tensile tests showed that PEEK-SP preserved 73.9% of the strength (71.06±2.17 MPa) and 73.4% of the elastic modulus (2.45±0.31 GPa) of as-received, injection-molded PEEK. PEEK-SP further demonstrated a fatigue strength of 60.0 MPa at one million cycles, preserving 73.4% of the fatigue resistance of injection-molded PEEK. Interfacial shear testing showed the pore layer shear strength to be 23.96±2.26 MPa. An osseointegration model in the rat revealed substantial bone formation within the pore layer at 6 and 12 weeks via microcomputed tomography and histological evaluation. Ingrown bone was more closely apposed to the pore wall and fibrous tissue growth was reduced in PEEK-SP when compared to non-porous PEEK controls. These results indicate that PEEK-SP could provide improved osseointegration while maintaining the structural integrity necessary for load-bearing orthopedic applications.

Citing Articles

A Comprehensive Review on Manufacturing and Characterization of Polyetheretherketone Polymers for Dental Implant Applications.

Kandula U, Monika D, Verma P, Rathi A, Saravanan P 3D Print Addit Manuf. 2024; 11(4):1441-1461.

PMID: 39360128 PMC: 11443112. DOI: 10.1089/3dp.2023.0064.


Nanoscale ZnO doping in prosthetic polymers mitigate wear particle-induced inflammation and osteolysis through inhibiting macrophage secretory autophagy.

Lyu Z, Meng X, Hu F, Wu Y, Ding Y, Long T Mater Today Bio. 2024; 28:101225.

PMID: 39309162 PMC: 11415586. DOI: 10.1016/j.mtbio.2024.101225.


Prospective applications of bioactive materials in orthopedic therapies: A review.

Liang W, Zhou C, Bai J, Zhang H, Long H, Jiang B Heliyon. 2024; 10(16):e36152.

PMID: 39247306 PMC: 11379564. DOI: 10.1016/j.heliyon.2024.e36152.


Surface modification of PEEK implants for craniofacial reconstruction and aesthetic augmentation-fiction or reality?.

Kauke-Navarro M, Knoedler L, Knoedler S, Deniz C, Safi A Front Surg. 2024; 11:1351749.

PMID: 38481611 PMC: 10936457. DOI: 10.3389/fsurg.2024.1351749.


High-Cycle Fatigue Behaviour of Polyetheretherketone (PEEK) Produced by Additive Manufacturing.

Rendas P, Imperadeiro A, Martins R, Soares B Polymers (Basel). 2024; 16(1).

PMID: 38201682 PMC: 10781079. DOI: 10.3390/polym16010018.


References
1.
Aspenberg P, Goodman S, Toksvig-Larsen S, Ryd L, Albrektsson T . Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits. Acta Orthop Scand. 1992; 63(2):141-5. DOI: 10.3109/17453679209154809. View

2.
Lin A, Barrows T, Cartmell S, Guldberg R . Microarchitectural and mechanical characterization of oriented porous polymer scaffolds. Biomaterials. 2002; 24(3):481-9. DOI: 10.1016/s0142-9612(02)00361-7. View

3.
Muller U, Imwinkelried T, Horst M, Sievers M, Graf-Hausner U . Do human osteoblasts grow into open-porous titanium?. Eur Cell Mater. 2006; 11:8-15. DOI: 10.22203/ecm.v011a02. View

4.
Oest M, Dupont K, Kong H, Mooney D, Guldberg R . Quantitative assessment of scaffold and growth factor-mediated repair of critically sized bone defects. J Orthop Res. 2007; 25(7):941-50. DOI: 10.1002/jor.20372. View

5.
Jockisch K, Brown S, Bauer T, Merritt K . Biological response to chopped-carbon-fiber-reinforced peek. J Biomed Mater Res. 1992; 26(2):133-46. DOI: 10.1002/jbm.820260202. View