» Articles » PMID: 25457780

Angular Stable Fixation of Displaced Distal-third Clavicle Fractures with Superior Precontoured Locking Plates

Overview
Date 2014 Dec 3
PMID 25457780
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Hypothesis: We reviewed the outcome of angular stable plates in addressing displaced lateral-third clavicle fractures. We investigated union, shoulder function, request for implant removal, and return to sport. Our hypothesis was that these implants provide predictable union and return to sports without the negative consequence of leaving plates in situ, reducing the requirement for a second surgery.

Methods: We undertook a retrospective review of a consecutive series of patients who underwent this surgery between 2007 and 2010. Nineteen patients with a mean follow-up of 25 months were included. Postoperative follow-up was performed at 2 weeks and monthly thereafter until union was assessed as achieved clinically and radiographically. Two telephone interviews at a mean of 7 months and 25 months postoperatively assessed shoulder function by Oxford Shoulder Score, presence of any plate or scar discomfort, need for implant removal, and return to sport.

Results: Nineteen patients achieved union by 4 months (median, 12 weeks; range, 6-16 weeks). The mean Oxford Shoulder Score was 46 (range, 41-48) at a mean of 7 months (range, 3-18 months) and 47 (range, 44-48) at 25 months (range, 18-48 months). Initially, 2 patients requested implant removal; later, however, both declined surgery. No plates have been removed. Four patients complained of mild plate discomfort but did not wish removal. All patients had returned to sporting activities.

Conclusion: Angular stable plate fixation of Neer group II, type II clavicle fractures resulted in a 100% union rate with excellent return of function with no mandatory need for removal.

Citing Articles

Distal augmentation in unstable distal clavicle fractures: a retrospective cohort study of 101 cases.

Tsai T, Hsu S, Hsu C, Liao C, Lu Y Arch Orthop Trauma Surg. 2025; 145(1):111.

PMID: 39776266 DOI: 10.1007/s00402-024-05731-6.


[Clavicular fractures : Diagnostics, treatment and management].

Prillwitz M, Tauber M, Martetschlager F Orthopadie (Heidelb). 2025; 54(2):157-165.

PMID: 39774719 DOI: 10.1007/s00132-024-04590-8.


Osteosynthesis using Scorpion plate for neer type V distal clavicle fracture.

Furuhata R, Matsumura N, Kamata Y, Tanji A BMC Musculoskelet Disord. 2024; 25(1):909.

PMID: 39543629 PMC: 11566308. DOI: 10.1186/s12891-024-08039-z.


Conformity of Three Pre-Contoured Clavicular Plates Compared Using Personalized 3D-Printed Models of Clavicles from Patients.

Song H, Joh Y, Kim H Life (Basel). 2024; 14(7).

PMID: 39063641 PMC: 11277846. DOI: 10.3390/life14070888.


Open reduction and tunneled suspensory fixation for lateral end of clavicle fractures: surgical technique.

Ahmed A, Salameh M, Kayali H, Hantouly A, Darwiche A JSES Rev Rep Tech. 2023; 2(3):345-349.