Digital Evaluation of the Accuracy of Impression Techniques and Materials in Angulated Implants

Overview
Journal J Dent
Publisher Elsevier
Specialty Dentistry
Date 2014 Dec 3
PMID 25446736
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants.

Methods: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10° or 20° angulated) were fabricated. Two different impression techniques [splinted direct (D), indirect (I)] and 3 different monophase impression materials [polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n=10). Master model and casts were scanned by a modified laser scanner and data were transferred to VRMesh software. Master model and duplicate cast scans were digitally aligned observing the superposition of anatomic markers. Angular and coronal deviations between master and duplicated copings were calculated and data were statistically analyzed.

Results: Mean angular and coronal deviations were in a range of 0.205-0.359° and 22.56-33.33μm, respectively. Statistical analysis revealed that the angulation of implant affected both coronal and angular deviations of the impression copings (P<0.05). According to statistical analyses, for parallel implants, the accuracy of impression materials and techniques were ranging as VPS-D=PE-D>VPS-I=PE-I>VPES-D>VPES-I from most accurate to the least. For 10° and 20° angulated implants the most accurate material and technique was VPS-D whereas the least accurate combination was VPES-I (P<0.05).

Conclusion: Angulation, impression technique and material were found to be effective on the accuracy of implant impressions.

Clinical Significance: Clinicians may prefer VPS impression material and splinted direct technique for impressions of both parallel and up to 20° angulated implants.

Citing Articles

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations.

Onoral O, Kurtulmus-Yilmaz S, Toksoy D, Ozan O J Adv Prosthodont. 2024; 15(6):290-301.

PMID: 38205122 PMC: 10774637. DOI: 10.4047/jap.2023.15.6.290.


Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions.

Akkal O, Korkmaz I, Bayindir F J Adv Prosthodont. 2023; 15(4):179-188.

PMID: 37662853 PMC: 10471506. DOI: 10.4047/jap.2023.15.4.179.


Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept.

Tas H, Demirci F, Tuzlali M, Bahce E, Yildirim Avcu G J Adv Prosthodont. 2023; 14(6):379-387.

PMID: 36685787 PMC: 9832145. DOI: 10.4047/jap.2022.14.6.379.


Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Djurovic Koprivica D, Puskar T, Budak I, Sokac M, Knezevic M, Maletin A Polymers (Basel). 2022; 14(14).

PMID: 35890598 PMC: 9315589. DOI: 10.3390/polym14142821.


The Accuracy of Open-Tray vs. Snap on Impression Techniques in A 6-Implant Model: An In Vitro 3D Study.

Arieli A, Adawi M, Masri M, Weinberg E, Beitlitum I, Pilo R Materials (Basel). 2022; 15(6).

PMID: 35329555 PMC: 8950925. DOI: 10.3390/ma15062103.