» Articles » PMID: 25441680

Adequacy and Complication Rates with 14- Vs. 16-gauge Automated Needles in Percutaneous Renal Biopsy of Native Kidneys

Overview
Journal Semin Dial
Specialty Nephrology
Date 2014 Dec 3
PMID 25441680
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

In performing percutaneous renal biopsy (PRB) of native kidneys, an increasing use of 16-gauge automated biopsy needles has been observed. We compare the adequacy and safety of PRBs in adults performed with a 14-gauge (n = 82) vs. 16-gauge (n = 55) automated needle using real-time ultrasound (US) from 1/2010 to 12/2013. Baseline clinical and laboratory data along with outcome data (renal US 1-hour postbiopsy, biopsy adequacy, and safety) were collected prospectively. There was no difference in age, gender, blood pressure, serum creatinine, or pre-PRB hemoglobin at baseline for PRBs performed with a 14- vs. 16-gauge needle. The number of glomeruli obtained per biopsy was similar (29 ± 11 vs. 31 ± 14, p = 0.6) and adequate tissue for diagnosis was obtained in 99% and 100% of biopsies. The clinical complication (8.5% vs. 9.1%, p = 1.0), transfusion (7.3% vs. 7.2%, p = 1.0), and embolization (3.7% vs. 1.8%, p = 0.6) rates were not significantly different for 14- vs. 16-gauge needles, but by routine renal US 1-hour post-PRB, a perinephric hematoma was demonstrated more often in biopsies done with the 14-gauge needle (39% vs. 22%, P 0.04). Thus, while the success of PRB of native kidneys is similar for both needle gauges, the potential for complication may be less using a 16-gauge automated needle.

Citing Articles

Image-guided renal parenchymal biopsies- how we do it.

Shyn P, Patel M, Itani M, Gupta A, Burgan C, Planz V Abdom Radiol (NY). 2024; .

PMID: 39585376 DOI: 10.1007/s00261-024-04690-1.


Cranial versus Caudal Direction Technique of Native Percutaneous Kidney Biopsy: A Randomized Controlled Trial.

Jaturapisanukul S, Chavanisakun C, Benjakul N, Ngamvichchukorn T, Laungchuaychok P, Kurathong S Int J Nephrol Renovasc Dis. 2023; 16:93-101.

PMID: 37013086 PMC: 10066630. DOI: 10.2147/IJNRD.S400639.


Postoperative and Recurrent Hematuria after Pretransplant Core Needle Biopsy in Living Donor Kidney Transplant.

Al-Adwan Y, Singh N, Chotai P, Siddiqui F, Limkemann A, Schenk A Case Rep Transplant. 2022; 2022:5274521.

PMID: 35937758 PMC: 9352472. DOI: 10.1155/2022/5274521.


Efficacy and safety of percutaneous renal biopsy performed using 18G needle versus 16G needle: a single-center retrospective study.

Xu S, Ma L, Lin J, Zhang Z, Wang X, Yin J Int Urol Nephrol. 2022; 54(12):3255-3261.

PMID: 35781773 PMC: 9605925. DOI: 10.1007/s11255-022-03276-4.


Kidney biopsy guidebook 2020 in Japan.

Ubara Y, Kawaguchi T, Nagasawa T, Miura K, Katsuno T, Morikawa T Clin Exp Nephrol. 2021; 25(4):325-364.

PMID: 33606126 PMC: 7966701. DOI: 10.1007/s10157-020-01986-6.