» Articles » PMID: 25408561

Bayesian Analysis of a One Compartment Kinetic Model Used in Medical Imaging

Overview
Journal J Appl Stat
Specialty Public Health
Date 2014 Nov 20
PMID 25408561
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Kinetic models are used extensively in science, engineering, and medicine. Mathematically, they are a set of coupled differential equations including a source function, otherwise known as an input function. We investigate whether parametric modeling of a noisy input function offers any benefit over the non-parametric input function in estimating kinetic parameters. Our analysis includes four formulations of Bayesian posteriors of model parameters where noise is taken into account in the likelihood functions. Posteriors are determined numerically with a Markov chain Monte Carlo simulation. We compare point estimates derived from the posteriors to a weighted non-linear least squares estimate. Results imply that parametric modeling of the input function does not improve the accuracy of model parameters, even with perfect knowledge of the functional form. Posteriors are validated using an unconventional utilization of the chi square test. We demonstrate that if the noise in the input function is not taken into account, the resulting posteriors are incorrect.

Citing Articles

Modeling PET Data Acquired During Nonsteady Conditions: What If Brain Conditions Change During the Scan?.

Morris E, Emvalomenos G, Hoye J, Meikle S J Nucl Med. 2024; 65(12):1824-1837.

PMID: 39448268 PMC: 11619587. DOI: 10.2967/jnumed.124.267494.


Mathematical Models for FDG Kinetics in Cancer: A Review.

Sommariva S, Caviglia G, Sambuceti G, Piana M Metabolites. 2021; 11(8).

PMID: 34436460 PMC: 8398381. DOI: 10.3390/metabo11080519.


Validation of Bayesian analysis of compartmental kinetic models in medical imaging.

Sitek A, Li Q, El Fakhri G, Alpert N Phys Med. 2016; 32(10):1252-1258.

PMID: 27692754 PMC: 5720163. DOI: 10.1016/j.ejmp.2016.09.010.


Sensitivity estimation in time-of-flight list-mode positron emission tomography.

Herraiz J, Sitek A Med Phys. 2015; 42(11):6690-702.

PMID: 26520759 PMC: 4627932. DOI: 10.1118/1.4934374.

References
1.
Huisman M, Higuchi T, Reder S, Nekolla S, Poethko T, Wester H . Initial characterization of an 18F-labeled myocardial perfusion tracer. J Nucl Med. 2008; 49(4):630-6. DOI: 10.2967/jnumed.107.044727. View

2.
Huesman R, Mazoyer B . Kinetic data analysis with a noisy input function. Phys Med Biol. 1987; 32(12):1569-79. DOI: 10.1088/0031-9155/32/12/004. View

3.
Stute S, Carlier T, Cristina K, Noblet C, Martineau A, Hutton B . Monte Carlo simulations of clinical PET and SPECT scans: impact of the input data on the simulated images. Phys Med Biol. 2011; 56(19):6441-57. DOI: 10.1088/0031-9155/56/19/017. View

4.
Mintun M, Larossa G, Sheline Y, Dence C, Lee S, Mach R . [11C]PIB in a nondemented population: potential antecedent marker of Alzheimer disease. Neurology. 2006; 67(3):446-52. DOI: 10.1212/01.wnl.0000228230.26044.a4. View

5.
Muzic Jr R, Christian B . Evaluation of objective functions for estimation of kinetic parameters. Med Phys. 2006; 33(2):342-53. DOI: 10.1118/1.2135907. View